Summary for Test 2019-08-02-26-2

Test performed: CTM 643-June 2007

Project Information

Project IdentifiersProject ID: 214344
DEA: 120P42U4
EFIS: 1216000097
DIST-CO-RTE-PM12-ORA-5,22,55,57,91,405-Var
Award Date09/15/2020
Closeout Date01/05/2026
Work DescriptionUpgrade and install Intelligent Transportation System (ITS) elements
Location DescriptionORANGE COUNTY
QA Service Level1 (Verified on 10/27/2020)

Sample Information

Sample Taken Date08/02/2019 Sample Unique Key26
Date that the sample was received by the laboratory/organization performing the testing08/08/2019 Sample typePer Request
A brief description of the sampleSoil The quantity of what the sample constitutes1 Ziplock bag
From where was the sample collectedJob Site First name of sampler or witnessed byKristopher
Last name of sampler or witnessed byBarker Title of samplerEngineering Geologist
Telephone number of sampler909-806-4701 Laboratory sample identification8673
Linked DIME Sample ID The fabricator/manufacturer/facility nameCaltrans
Transportation Laboratory (TL) NumberK-0P42U-1 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sampleUnknown
The fabricator/manufacturer designation for the sampleUnknown A detailed description of where the material sample was collectedBoring No. HA-2
Where the material sample would have been placed if not sampledUnknown

Test Details

DIME Sample ID: 2019-08-02-26
DIME Test ID: 2019-08-02-26-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 643-June 2007: Method for Determining Field and Laboratory Resistivity and pH Measurements for Soil and Water
Test Release Date: 2019-09-18

Test Results


The test method used?: Laboratory Resistivity Test for Soil
Input Type: Calculated
Tester's full name: Tess Perez
Date of test: 08/13/2019
Soil sample resistance (lab measure 1): no data Ohms
Soil sample resistance (lab measure 2): no data Ohms
Soil sample resistance (lab measure 3): no data Ohms
Soil sample resistance (lab measure 4): no data Ohms
Soil sample resistance (lab measure 5): no data Ohms
Soil sample resistance (lab measure 6): no data Ohms
Soil sample resistance (lab measure 7): no data Ohms
Soil sample resistance (lab measure 8): no data Ohms
Soil sample resistance (lab measure 9): no data Ohms
Soil sample resistance (lab measure 10): no data Ohms
Soil sample resistance (lab measure 11): no data Ohms
Soil sample resistance (lab measure 12): no data Ohms
Minimum soil resistance of the lab measurement: 4600 Ohms
Soil sample temperature: 21.7 C
Soil box constant: 1
pH of soil: 7.80
Minimum soil resistance corrected to 15.5: 5313 Ohms
Minimum soil resistivity at 15.5: 5313 Ohm-cm
General comments (publicly viewable) (Max 1000 characters): Estimated Life = 50 years

Test was verified on 9/18/2019 ✔