Summary for Test 2019-06-27-31-9
Test performed: CTM 643-June 2007Project Information
| Project Identifiers | Project ID: 214342 DEA: 081F9904 EFIS: 0815000095 |
|---|---|
| DIST-CO-RTE-PM | 08-SBD-15-40.1/40.5 |
| Award Date | 06/15/2020 |
| Closeout Date | 08/02/2021 |
| Work Description | LENGTHEN ACCELERATION LANE |
| Location Description | VICTORVILLE FROM 0.5 MILE TO 0.1 MILE SOUTH OF PALMDALE ROAD OVERCROSSING |
| QA Service Level | 1 (Verified on 10/06/2020) |
Sample Information
| Sample Taken Date | 06/27/2019 | Sample Unique Key | 31 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 07/15/2019 | Sample type | Informational |
| A brief description of the sample | Soil | The quantity of what the sample constitutes | 1 bag |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | Jose |
| Last name of sampler or witnessed by | Guzman | Title of sampler | MREA |
| Telephone number of sampler | 909-829-6292 | Laboratory sample identification | 8647 |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Caltrans | |
| Transportation Laboratory (TL) Number | 8647 | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Soil | The fabricator's/manufacturer's product name for the sample | Unknown |
|---|---|---|---|
| The fabricator/manufacturer designation for the sample | Unknown | A detailed description of where the material sample was collected | A-19-002 |
| Where the material sample would have been placed if not sampled | Unknown |
Test Details
DIME Sample ID: 2019-06-27-31
DIME Test ID: 2019-06-27-31-9
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 643-June 2007: Method for Determining Field and Laboratory Resistivity and pH Measurements for Soil and Water
Test Release Date: 2019-09-16
Test Results
The test method used?: Laboratory Resistivity Test for Soil
Input Type: Calculated
Tester's full name: Kiet Phan
Date of test: 07/19/2019
Soil sample resistance (lab measure 1): no data Ohms
Soil sample resistance (lab measure 2): no data Ohms
Soil sample resistance (lab measure 3): no data Ohms
Soil sample resistance (lab measure 4): no data Ohms
Soil sample resistance (lab measure 5): no data Ohms
Soil sample resistance (lab measure 6): no data Ohms
Soil sample resistance (lab measure 7): no data Ohms
Soil sample resistance (lab measure 8): no data Ohms
Soil sample resistance (lab measure 9): no data Ohms
Soil sample resistance (lab measure 10): no data Ohms
Soil sample resistance (lab measure 11): no data Ohms
Soil sample resistance (lab measure 12): no data Ohms
Minimum soil resistance of the lab measurement: 6200 Ohms
Soil sample temperature: 21.9 C
Soil box constant: 1
pH of soil: 8.22
Minimum soil resistance corrected to 15.5: 7192 Ohms
Minimum soil resistivity at 15.5: 7192 Ohm-cm
General comments (publicly viewable) (Max 1000 characters): Estimated Life = 56 Years
Test was verified on 9/16/2019 ✔