Summary for Test 2019-06-27-28-12
Test performed: CTM 301-March 2000Project Information
| Project Identifiers | Project ID: 214339 DEA: 081G0004 EFIS: 0815000107 |
|---|---|
| DIST-CO-RTE-PM | 08-RIV-95-14.5/35.6 |
| Award Date | 11/04/2020 |
| Closeout Date | 03/01/2022 |
| Work Description | CONSTRUCT CONCRETE/RSP APRONS |
| Location Description | RIVERSIDE COUNTY AT VARIOUS LOCATIONS FROM 4 MILES NORTH OF PALO VERDE DAM ROAD TO 0.6 MILE SOUTH OF SAN BERNARDINO COUNTY LINE |
| QA Service Level | 1 (Verified on 12/02/2020) |
Sample Information
| Sample Taken Date | 06/27/2019 | Sample Unique Key | 28 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 06/28/2019 | Sample type | Preliminary |
| A brief description of the sample | Soil obtained from depth of 5' | The quantity of what the sample constitutes | 1 bag |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | Jose |
| Last name of sampler or witnessed by | Guzman | Title of sampler | MREA |
| Telephone number of sampler | Laboratory sample identification | 8635 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Caltrans | |
| Transportation Laboratory (TL) Number | 8635 | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Soil | The fabricator's/manufacturer's product name for the sample | Unknown |
|---|---|---|---|
| The fabricator/manufacturer designation for the sample | Unknown | A detailed description of where the material sample was collected | Rte 95, PM 35.68, Outside shoulder |
| Where the material sample would have been placed if not sampled | Unknown |
Test Details
DIME Sample ID: 2019-06-27-28
DIME Test ID: 2019-06-27-28-12
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 301-March 2000: Method for Determining the Resistance "R" Value of Treated and Untreated Bases, Subbases, and Basement Soils by the Stabilometer
Test Release Date: 2019-09-12
Test Results
How will the R value be determined?: By stabilometer
Input Type: Calculated
Tester's full name: Tess perez/Kiet Phan
Date of test: 07/10/2019
As Received Gradation, Percent Passing 3 in. sieve: 100 %
As Received Gradation, Percent Passing 2 1/2 in. sieve: 100 %
As Received Gradation, Percent Passing 2 in. sieve: 100 %
As Received Gradation, Percent Passing 1 1/2 in. sieve: 100 %
As Received Gradation, Percent Passing 1 in. sieve: 96 %
As Received Gradation, Percent Passing 3/4 in. sieve: 91 %
As Received Gradation, Percent Passing 1/2 in. sieve: 80 %
As Received Gradation, Percent Passing 3/8 in. sieve: 74 %
As Received Gradation, Percent Passing #4 sieve: 59 %
As Received Gradation, Percent Passing #8 sieve: 47 %
As Received Gradation, Percent Passing #16 sieve: 38 %
As Received Gradation, Percent Passing #30 sieve: 29 %
As Received Gradation, Percent Passing #50 sieve: 18 %
As Received Gradation, Percent Passing #100 sieve: 9 %
As Received Gradation, Percent Passing #200 sieve: 5.3 %
As Used Gradation, Percent Passing 3 in. sieve: 100 %
As Used Gradation, Percent Passing 2 1/2 in. sieve: 100 %
As Used Gradation, Percent Passing 2 in. sieve: 100 %
As Used Gradation, Percent Passing 1 1/2 in. sieve: 100 %
As Used Gradation, Percent Passing 1 in. sieve: 96 %
As Used Gradation, Percent Passing 3/4 in. sieve: 91 %
As Used Gradation, Percent Passing 1/2 in. sieve: 80 %
As Used Gradation, Percent Passing 3/8 in. sieve: 74 %
As Used Gradation, Percent Passing #4 sieve: 59 %
As Used Gradation, Percent Passing #8 sieve: 47 %
As Used Gradation, Percent Passing #16 sieve: 38 %
As Used Gradation, Percent Passing #30 sieve: 29 %
As Used Gradation, Percent Passing #50 sieve: 18 %
As Used Gradation, Percent Passing #100 sieve: 9 %
As Used Gradation, Percent Passing #200 sieve: 5.3 %
R value: 72
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/12/2019 ✔