Summary for Test 2019-08-13-9-1
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 213283 DEA: 060U09U4 EFIS: 0616000243 |
---|---|
DIST-CO-RTE-PM | 06-FRE-168-R36.0/65.9 |
Award Date | 08/24/2018 |
Closeout Date | 01/31/2020 |
Work Description | HMA RESURFACING AND REHAB CULVERTS |
Location Description | FRESNO COUNTY IN AND NEAR SHAVER LAKE FROM 0.2 MILE WEST OF AUBERRY ROAD TO KAISER PASS ROAD |
QA Service Level | 1 (Verified on 09/25/2018) |
Sample Information
Sample Taken Date | 08/13/2019 | Sample Unique Key | 9 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/12/2019 |
Sample type | Dispute Resolution | A brief description of the sample | 3/4 inch HMA 15%RAP |
The quantity of what the sample constitutes | 2 | From where was the sample collected | Source |
First name of sampler or witnessed by | M | Last name of sampler or witnessed by | Shirvani |
Title of sampler | TE | Telephone number of sampler | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Millbrook construction Fresno Security Paving | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | Unknown |
Sublot number | Unknown | HMA Mix Number | Not set |
Test Details
DIME Sample ID: 2019-08-13-9
DIME Test ID: 2019-08-13-9-1
Testing Lab: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2019-12-17
Test Results
What temperature unit is used?: Fahrenheit
Input Type: Measured
Tester's full name: Gurpartap Grewal
Date of test: 08/29/2019
Test procedure used?: Method B
Mass of the specimen basket assembly: no data
Mass of the specimen and specimen basket assembly prior to ignition: no data
Mass of HMA Sample prior to ignition: 2282.4 g
Mass Loss: no data
Mass of aggregate remaining after ignition: 2172.6 g
Correction Factor (Percent by mass of HMA Specimen): 0.17 %
Moisture Content: 0.16 %
Temperature Compensation Factor: no data
Test Temperature: 538 F
Corrected Asphalt Binder Content: 4.48 %
General comments (publicly viewable) (Max 1000 characters): Translab internal lab no. 019-024
Dispute Resolution
AASHTO T-308
Test was verified on 12/17/2019 ✔