Summary for Test 2014-08-05-2-1

Test performed: CTM 202-November 2011

Project Information

Project IdentifiersProject ID: 208798
DEA: 080R1904
EFIS: 0812000031
DIST-CO-RTE-PM08-RIV-74-23.1
Award Date04/03/2014
Closeout Date05/11/2015
Work DescriptionINSTALL LIGHTING AND TRAFFIC SIGNALS.
Location DescriptionRIVERSIDE COUNTY NEAR PERRIS AT THEDA STREET
QA Service Level1 (Verified on 04/16/2014)

Sample Information

Sample Taken Date08/05/2014 Sample Unique Key2
Date that the sample was received by the laboratory/organization performing the testing08/05/2014 Sample typeAnnual Source Testing
A brief description of the sample1 and a half inch rock The quantity of what the sample constitutes8 Bags
From where was the sample collectedSource First name of sampler or witnessed byTom
Last name of sampler or witnessed byMilum Title of samplerQC Technician
Telephone number of sampler Laboratory sample identification4208B
Linked DIME Sample IDNot set The fabricator/manufacturer/facility nameRobertsons Banning Quarry
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-33-0012::BANNING QUARRY
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedStockpiles
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1-1/2 inch
The concrete mix design number Lot numberNot set
Sublot numberNot set Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2014-08-05-2
DIME Test ID: 2014-08-05-2-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2015-02-20

Test Results


What size aggregate is being tested?: 1.5 in. x 0.75 in. - Coarse Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Calculated
Tester's full name: Nader Rashidi
Date of test: 08/07/2014
Sieve SizeCumulative Percent Passing
100 %
100 %
36 %
3 %
%
%
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 2/20/2015 ✔