Summary for Test 2019-05-29-36-1
Test performed: AASHTO T209-12Project Information
| Project Identifiers | Project ID: 213793 DEA: 060W7004 EFIS: 0617000283 |
|---|---|
| DIST-CO-RTE-PM | 06-FRE-33-24.3/R29.0,R39.9/44.5 |
| Award Date | 01/24/2019 |
| Closeout Date | 08/20/2021 |
| Work Description | COLD PLANE AC PAVEMENT, PLACE HMA RESURFACING. |
| Location Description | FRESNO COUNTY ABOUT 7.8 MILES NORTH OF COALINGA FROM NORTH JUNCTION ROUTE 198 TO SOUTH JUNCTION ROUTE 33/5 AND FROM 0.1 MILE NORTH OF NORTH JUNCTION ROUTE 33/5 TO EL PROGRESSIO ROAD |
| QA Service Level | 1 (Verified on 01/09/2019) |
Sample Information
| Sample Taken Date | 05/29/2019 | Sample Unique Key | 36 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 07/12/2019 | Sample type | Dispute Resolution |
| A brief description of the sample | 1/2 inch HMA with 15%RAP | The quantity of what the sample constitutes | 4 |
| From where was the sample collected | Source | First name of sampler or witnessed by | M Stavro |
| Last name of sampler or witnessed by | Poulos | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Millbrook construction Fresno Papich Construction | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 1/2 inch | Lot number | 1 |
| Sublot number | 3 | HMA Mix Number | Not set |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2019-05-29-36
DIME Test ID: 2019-05-29-36-1
Testing Lab: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2019-12-17
Test Results
Number of tests: 1
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Water
Input Type: Measured
Tester's full name: Gurpartap Grewal
Date of test: 08/28/2019
Method Performed: no data
Mass of oven-dry sample in air for Sample 1: 1519 grams
Mass of sample in water for Sample 1: 900 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 2.454
Theoretical maximum density at 25°C (77°F): no data
General comments (publicly viewable) (Max 1000 characters): Translab internal lab no.: 019-014
Dispute Resolution
Lot1 SL5 T-209
Test was verified on 12/17/2019 ✔