Summary for Test 2019-04-15-18-1
Test performed: AASHTO T209-12Project Information
| Project Identifiers | Project ID: 213050 DEA: 051J5204 EFIS: 0517000195 |
|---|---|
| DIST-CO-RTE-PM | 05-SLO-58-6.9/30.0 |
| Award Date | 03/19/2018 |
| Closeout Date | 12/30/2019 |
| Work Description | COLD PLANE EXISTING ROADWAY AND RESURFACE WITH RHMA-G. |
| Location Description | SAN LUIS OBISPO COUNTY ABOUT 6 MILES EAST OF SANTA MARGARITA FROM ROUTE 229 TO NAVAJO CREEK BRIDGE |
| QA Service Level | 1 (Verified on 09/06/2019) |
Sample Information
| Sample Taken Date | 04/15/2019 | Sample Unique Key | 18 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 04/15/2019 | Sample type | Dispute Resolution |
| A brief description of the sample | 3/4 inch RHMA-G | The quantity of what the sample constitutes | 1 |
| From where was the sample collected | Source | First name of sampler or witnessed by | B |
| Last name of sampler or witnessed by | Barber | Title of sampler | TET |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Papich Construction | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | 3 |
| Sublot number | 1 | HMA Mix Number | Not set |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2019-04-15-18
DIME Test ID: 2019-04-15-18-1
Testing Lab: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2019-12-17
Test Results
Number of tests: 1
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Water
Input Type: Calculated
Tester's full name: Gurpartap Grewal
Date of test: 04/16/2019
Specific Gravity for Sample 1: 2.381
Theoretical maximum density at 25°C (77°F): no data
General comments (publicly viewable) (Max 1000 characters): Translab internal lab no.: 019-004
CT Lab No.: 18-A-518
Lot3 Sublot1
Test was verified on 12/17/2019 ✔