Summary for Test 2019-08-08-28-3
Test performed: ASTM A416-15Project Information
Project Identifiers | Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 08/08/2019 | Sample Unique Key | 28 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/12/2019 |
Sample type | Quality Assurance | A brief description of the sample | Prestressing Strand |
The quantity of what the sample constitutes | 31 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Don | Last name of sampler or witnessed by | Hiranaga |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Sumiden Wire | Transportation Laboratory (TL) Number | NA |
Inspector Lot Number from the Transportation Laboratory (TL) Form | NA | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM4 - Prestressing Strand | Comments | Unknown |
---|---|---|---|
Reel/Coil/Pack Number(s) | Number of Coils | Unknown | |
Group Number | 10923 | Strand Diameter | .6 in |
Grade | 270 | Strand Specification | ASTM A 416 |
Heat Number(s) | S0502919, S0592719, S0503219, S0503519 | Mfg. Lot Number(s) | NA |
Manufacturer(s) | Sumiden Wire |
Test Details
DIME Sample ID: 2019-08-08-28
DIME Test ID: 2019-08-08-28-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Test Release Date: 2019-08-21
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 08/21/2019
UTM: 120kip
Temperature: 72 f
Extensometers: no data
Num | Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By |
---|---|---|---|---|---|---|---|---|
1 | S0503219 | S334963-1 | 0.217 | 59838.7 | 54866.1 | 28.3 | 2.08 | bewing |
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Bluehill Data Point FileTest graph for the Sample
Test was verified on 8/21/2019 ✔