Summary for Test 2019-07-22-20-2

Test performed: AASHTO T27-14

Project Information

Project IdentifiersProject ID: 213877
DEA: 060X8904
EFIS: 0618000179
DIST-CO-RTE-PM06-KIN-41-0.0/11.5
Award Date03/15/2019
Closeout Date04/16/2021
Work DescriptionCOLD PLANE AC PAVEMENT AND PLACE RHMA TYPE G.
Location DescriptionKINGS COUNTY ABOUT 6.5 MILES SOUTH OF KETTLEMAN CITY FROM KERN COUNTY LINE TO 0.1 MILE SOUTH OF UTICA AVENUE
QA Service Level1 (Verified on 04/11/2019)

Sample Information

Sample Taken Date07/22/2019 Sample Unique Key20
Date that the sample was received by the laboratory/organization performing the testing07/26/2019 Sample typeQuality Assurance
A brief description of the samplesublot 15 The quantity of what the sample constitutes1 bag
From where was the sample collectedOther First name of sampler or witnessed byna
Last name of sampler or witnessed byna Title of samplerna
Telephone number of sampler Laboratory sample identification19-RHMA-0127
Linked DIME Sample ID The fabricator/manufacturer/facility namesample from plant
Transportation Laboratory (TL) NumberC816176-15 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)SPM Avenal CA
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedplant
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size1/2 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot number15 Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2019-07-22-20
DIME Test ID: 2019-07-22-20-2
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2019-08-19

Test Results


What type of gradation is being tested?: HMA Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): Yes
Has the fine aggregate sample been reduced?: No
Input Type: Measured
Tester's full name: PM/RK/JH
Date of test: 08/01/2019
Cumulative Mass RetainedCumulative Percent Passing
2833.2 grams
grams %
0.0 grams100 %
0.0 grams100 %
0.0 grams100 %
72.1 grams97.5 %
419.5 grams85.2 %
0 grams100 %
1746.6 grams38.4 %
316.2 grams16.2 %
403.3 grams10.1 %
452.0 grams6.7 %
481.1 grams4.7 %
497.4 grams3.5 %
509.9 grams2.67 %
grams
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/19/2019 ✔