Summary for Test 2019-08-01-3-1

Test performed: AASHTO T27-14

Project Information

Project IdentifiersProject ID: 214122
DEA: 081G1204
DIST-CO-RTE-PM08-RIV-243-13.3/29.7
Award Date06/12/2019
Closeout Date03/25/2020
Work DescriptionCOLD PLANE AC, PLACE RHMA-G AND RECESSED THERMOPLASTIC TRAFFIC STRIPE.
Location DescriptionRIVERSIDE COUNTY IN AND NEAR BANNING FROM 0.7 MILE NORTH OF BLACK MOUNTAIN TRAIL TO ROUTE 243/10 SEPARATION
QA Service Level1 (Verified on 03/25/2020)

Sample Information

Sample Taken Date08/01/2019 Sample Unique Key3
Date that the sample was received by the laboratory/organization performing the testing08/02/2019 Sample typeVerification
A brief description of the sample3/4 RHMA-G-SP The quantity of what the sample constitutesJMF 6 bags
From where was the sample collectedManufacturer First name of sampler or witnessed byMatich Cabazon
Last name of sampler or witnessed byQC Title of sampler
Telephone number of sampler Laboratory sample identification0457G-19
Linked DIME Sample ID The fabricator/manufacturer/facility nameRobertsons Cabazon, Cemex Lytle Creek
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-33-0008, 91-36-0040
The fabricator's/manufacturer's product name for the sample3/4 RHMA-G-SP The fabricator/manufacturer designation for the sampleCHP-68E
The plant numberUnknown A detailed description of where the material sample was collectedBelt Cut at Matich Cabazon Plant
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size3/4 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2019-08-01-3
DIME Test ID: 2019-08-01-3-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2019-08-22

Test Results


What type of gradation is being tested?: HMA Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): Yes
Has the fine aggregate sample been reduced?: No
Input Type: Calculated
Tester's full name: Sebastian Ferrer, Husni Ankir
Date of test: 08/05/2019
Cumulative Percent Passing
%
100 %
100 %
96 %
85 %
72 %
72 %
41 %
22 %
15 %
10 %
7 %
5 %
2.9 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/22/2019 ✔