Summary for Test 2019-07-22-17-8
Test performed: AASHTO T304-11Project Information
Project Identifiers | Project ID: 214013 DEA: 120R2804 EFIS: 1218000075 |
---|---|
DIST-CO-RTE-PM | 12-ORA,LA-39-17.4/19.1 |
Award Date | 05/01/2019 |
Closeout Date | 03/27/2020 |
Work Description | COLD PLANE AC AND PLACE RHMA-G. |
Location Description | ORANGE AND LOS ANGELES COUNTIES IN LA MIRADA AND LA HABRA FROM ROSECRANS AVENUE TO WESTRIDGE PLAZA NORTH |
QA Service Level | 1 (Verified on 05/31/2019) |
Sample Information
Sample Taken Date | 07/22/2019 | Sample Unique Key | 17 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/29/2019 |
Sample type | Verification | A brief description of the sample | 1/2 RHMA-G-SP |
The quantity of what the sample constitutes | PSE 3 bags | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | C | Last name of sampler or witnessed by | Pham |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 0443G-19 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Hanson Aggregates, Mayhew Aggregates | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-33-0035, 91-33-0039 |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | 1/2 RHMA-G-SP | The fabricator/manufacturer designation for the sample | 50R003ARSPO |
The plant number | Unknown | A detailed description of where the material sample was collected | Belt Cut at RJ Noble Orange Plant |
Where the material sample would have been placed if not sampled | Unknown | Primary Aggregate Nominal Size | 1/2 inch |
The concrete mix design number | Unknown | Lot number | Unknown |
Sublot number | Unknown | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2019-07-22-17
DIME Test ID: 2019-07-22-17-8
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)
Test Release Date: 2019-08-22
Test Results
What test method is performed?: Method A
Input Type: Calculated
Tester's full name: Danilo Ferrer
Date of test: 07/30/2019
Bulk dry specific gravity: 2.591
Average uncompacted voids: 46.4 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/22/2019 ✔