Summary for Test 2019-07-30-5-9

Test performed: ASTM F606-14a

Project Information

Project IdentifiersProject ID: 213267
DEA: 04013584
EFIS: 0416000289
DIST-CO-RTE-PM04-SF-80-8.0/8.3,0.9/1.4
Award Date03/29/2018
Closeout Date12/30/2019
Work DescriptionPier Retention
Location DescriptionIn San Francisco and Alameda Counties on Yerba Buena Island and .4 miles west of Oakland Toll plaza
QA Service Level1 (Verified on 05/01/2018)

Sample Information

Sample Taken Date07/30/2019 Sample Unique Key5
Date that the sample was received by the laboratory/organization performing the testing07/31/2019 Sample typeQuality Assurance
A brief description of the sampleA325 HDG Bolt The quantity of what the sample constitutes26,
From where was the sample collectedFabricator First name of sampler or witnessed byRick
Last name of sampler or witnessed byBettencourt Title of samplerQA Inspector
Telephone number of sampler2092015432 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameTC Steel
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) FormS25-107-19
Structure unique identifier Structure namePier Retention Oakland
Bid ItemNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s)100890222, 100793765, 100793042, 10552460-66, 10472160-58, 10556940, 10397940, Nut Mfg. Lot Number(s)18-04-008, 18-04-008, 18-04-008,30586-6214705705, 391903A, 30380-S-189067, 29633-75073529
Washer Mfg. Lot Number(s)0119-045,0119-045,0119-045, 0419-143, 1018-988, 0319-116, 1218-036, Bolt SpecificationA325
Bolt Length(s)2", 1-3/4", 1-1/4", 2", 4-1/2", 4", 3" Nut SpecificationA563
Washer SpecificationF436 FinishHDG
Diameter/Size1/2", 1/2", 1/2", 1", 7/8", 3/4", 5/8" Bolt Mfg. Lot Number403427A,411456A,413210B, 811609, 780909, 8119
Rocap Test Requirement(s) Lubricant Requirements(s)
Washer Inner Diameter(s) Bolt Mill SupplierNot set
Nut Mill SupplierNot set Washer Mill SupplierNot set

Test Details

DIME Sample ID: 2019-07-30-5
DIME Test ID: 2019-07-30-5-9
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2019-08-14

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Steve
Date of test: 08/08/2019
UTM: 400KIP
Temperature: 72 F
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
15A30380-S-189067?\"50602225.09Nut Proof LoadSteve

General comments (publicly viewable) (Max 1000 characters): Nut Proof Load
Test Graph
Source: Partner Data Point File

Test was verified on 8/14/2019 ✔