Summary for Test 2019-07-29-3-1

Test performed: ASTM F606-14a

Project Information

Project IdentifiersProject ID: 208945
DEA: 07288604
EFIS: 0700021080
COOP: 074663
DIST-CO-RTE-PM07-LA-710-6.0-9.4
Award Date09/02/2011
Closeout DateNot set
Work DescriptionGerald Desmond Bridge Replacement - A Design Build project. IQA samples will be selected by Port/Caltrans representatives and sent to Translab for testing.
Location DescriptionPort of Long Beach (District 7)
QA Service Level1 (Verified on 06/03/2013)

Sample Information

Sample Taken Date07/29/2019 Sample Unique Key3
Date that the sample was received by the laboratory/organization performing the testing07/29/2019 Sample typeQuality Assurance
A brief description of the sampleA490 Fastener Assembly The quantity of what the sample constitutes70
From where was the sample collectedJob Site First name of sampler or witnessed byNicholas
Last name of sampler or witnessed byHoffmann Title of samplerIQA Inspector
Telephone number of sampler5105429827 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameLeJeune Bolt Company
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure nameGerald Desmond Bridge
Bid ItemNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s)Bolt 10531190 Nut 6214661005 Washer 140647 Nut Mfg. Lot Number(s)
Washer Mfg. Lot Number(s) Bolt Specification1 1/4-7 x 4 1/4 F3125 Grade A490
Bolt Length(s)4" Nut Specification1 1/4-7 A563 DH
Washer Specification1 1/4 F436 Finish
Diameter/SizeUnknown Bolt Mfg. Lot Number
Rocap Test Requirement(s) Lubricant Requirements(s)
Washer Inner Diameter(s) Bolt Mill SupplierNot set
Nut Mill SupplierNot set Washer Mill SupplierNot set

Test Details

DIME Sample ID: 2019-07-29-3
DIME Test ID: 2019-07-29-3-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2019-08-07

Test Results


Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: Steve
Date of test: 08/06/2019
UTM: 400KIP
Temperature: no data
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
11A28201-10531190Z1.25\"162044720.86A490Steve

General comments (publicly viewable) (Max 1000 characters): A490
Test Graph
Source: Partner Data Point File

Test was verified on 8/7/2019 ✔