Summary for Test 2019-07-18-10-16
Test performed: ASTM B499-14Project Information
| Project Identifiers | Project ID: 213600 DEA: 060T3014 EFIS: 0616000183 |
|---|---|
| DIST-CO-RTE-PM | 06-KER-14-16.6/16.6 |
| Award Date | 11/09/2018 |
| Closeout Date | 11/17/2021 |
| Work Description | CONSTRUCT CREW BUILDING EQUIPMENT BUILDING AND RINSE FACILITY. |
| Location Description | KERN COUNTY AT MOJAVE AT THE MOJAVE HIGHWAY MAINTENANCE STATION AT 2211 NADEAU STREET |
| QA Service Level | 1 (Verified on 12/07/2018) |
Sample Information
| Sample Taken Date | 07/18/2019 | Sample Unique Key | 10 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 07/23/2019 | Sample type | Quality Assurance |
| A brief description of the sample | F1554 Gr. 36 Rod | The quantity of what the sample constitutes | 32,48 |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | Sherri |
| Last name of sampler or witnessed by | Brannon | Title of sampler | Quality Assurance Inspector |
| Telephone number of sampler | 916-826-6371 | Laboratory sample identification | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Portland Bolt Manufacturing | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
|---|---|---|---|
| Heat Number(s) | 3083960, 1202010894 | Nut Mfg. Lot Number(s) | 30380-S-189067, 30586-6214705705 |
| Washer Mfg. Lot Number(s) | 0319-116,0419-143 | Bolt Specification | F1554 Gr. 36 Rod |
| Bolt Length(s) | 33, 43, 33 | Nut Specification | A563 DH HVY HX |
| Washer Specification | F436 | Finish | HDG |
| Diameter/Size | 3/4, 1 | Bolt Mfg. Lot Number | NA |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | Blue Dye | |
| Washer Inner Diameter(s) | Bolt Mill Supplier | Not set | |
| Nut Mill Supplier | Not set | Washer Mill Supplier | Not set |
Test Details
DIME Sample ID: 2019-07-18-10
DIME Test ID: 2019-07-18-10-16
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Test Release Date: 2019-07-26
Test Results
Input Type: Calculated
Tester's full name: Fred Saylor
Date of test: 07/25/2019
Sample No.: 3A
Rocap Number: no data
Heat Number(s): no data
Mfg. Lot Number: 30586-6214705705
Finish Coating: Plain and A153 and F2329
Product Markings: U DH
Size: 1 in
Bolt Length: no data
Measurement Average: 3.76 mils
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/26/2019 ✔