Summary for Test 2019-06-27-4-1

Test performed: ASTM C39-17a

Project Information

Project IdentifiersProject ID: 212897
DEA: 042J5604
EFIS: 0414000529
DIST-CO-RTE-PM04-MRN-1-0.3
Award Date11/09/2018
Closeout Date12/17/2019
Work DescriptionREPAIR ROADWAY SLIP-OUT
Location DescriptionIN MARIN COUNTY NEAR MILL VALLEY ROAD AT 0.1 MILE EAST OF TENNESSEE VALLEY ROAD
QA Service Level1 (Verified on 06/04/2019)

Sample Information

Sample Taken Date06/27/2019 Sample Unique Key4
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/03/2019
Sample typeQuality Assurance A brief description of the sample6x12 concrete cylinders
The quantity of what the sample constitutes8 CY From where was the sample collectedJob Site
First name of sampler or witnessed byJeremy Last name of sampler or witnessed byLight
Title of samplerStructure Representative Telephone number of sampler5103939273
Laboratory sample identification1-28-1 of 2, 2 of 2 Linked DIME Sample ID
The fabricator/manufacturer/facility nameSuperior Concrete Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier27-E0074
Structure nameMill Valley Retaining Wall Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number675CIDH
The truck number from where the sample was collected0055 The batch plant ticket number from where the sample was collected272556
Concrete batch plantSuperior Supplier The fabricator/manufacturer designation for the sampleUnknown
A detailed description of where the material sample was collectedfrom chute Where the material sample would have been placed if not sampledsoldier piles
From Lot No.Unknown Bag Lot No.Unknown

Test Details

DIME Sample ID: 2019-06-27-4
DIME Test ID: 2019-06-27-4-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2019-07-25

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: RM
Date of test: 07/25/2019
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.05 in
Average diameter of cylinder 2: 6.03 in
Maximum load on cylinder 1: 151845 lb
Maximum load on cylinder 2: 142197 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Age of specimen: 28 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 28.73 in^2
Cross sectional area of cylinder 2: 28.54 in^2
Compressive strength of cylinder 1: 5285.2 psi
Compressive strength of cylinder 2: 4982.4 psi
Compressive strength (to nearest 10 psi): 5130 psi
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point File
Test graph for Cylinder Code 1 of 2

Source: Partner Data Point File
Test graph for Cylinder Code 2 of 2

Test was verified on 7/25/2019