Summary for Test 2019-06-13-7-6

Test performed: AASHTO T176-08

Project Information

Project IdentifiersProject ID: 213738
DEA: 07303504
EFIS: 0714000007
DIST-CO-RTE-PM07-VEN-23-0.0/R3.3
Award Date01/09/2019
Closeout Date11/02/2020
Work DescriptionCOLD PLANE & OVERLAY ASPHALT CONCRETE PAVEMENT AND UPGRADE CURB RAMPS.
Location DescriptionVENTURA COUNTY IN THOUSAND OAKS FROM CARLISLE ROAD TO ROUTE 101
QA Service Level1 (Verified on 11/02/2020)

Sample Information

Sample Taken Date06/13/2019 Sample Unique Key7
Date that the sample was received by the laboratory/organization performing the testing06/19/2019 Sample typeVerification
A brief description of the sample1/2 RHMA-G-SP The quantity of what the sample constitutesJMF 9 bags
From where was the sample collectedManufacturer First name of sampler or witnessed byVulcan Sun Valley
Last name of sampler or witnessed byQC Title of sampler
Telephone number of sampler Laboratory sample identification0359G-19
Linked DIME Sample ID The fabricator/manufacturer/facility nameSheldon, Boulevard, Big Rock Creek
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)Sheldon, Boulevard, Big Rock Creek
The fabricator's/manufacturer's product name for the sample1/2 RHMA-G-SP The fabricator/manufacturer designation for the sample326120 SVA3 LTR
The plant number3 A detailed description of where the material sample was collectedBelt Cut at Plant
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size1/2 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2019-06-13-7
DIME Test ID: 2019-06-13-7-6
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Test Release Date: 2019-08-22

Test Results


How many times will the test be run?: 3 Times
Input Type: Measured
Tester's full name: Husni Ankir
Date of test: 06/28/2019
Clay Level (Test 1): 4.9
Sand Level (Test 1): 4
Clay Level (Test 2): 4.9
Sand Level (Test 2): 4
Clay Level (Test 3): 5.2
Sand Level (Test 3): 4.2
Sand Equivalent (Test 1): 82
Sand Equivalent (Test 2): 82
Sand Equivalent (Test 3): 81
Sand Equivalent: 82
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/22/2019 ✔