Summary for Test 2019-06-26-1-3

Test performed: ASTM A970-15e1

Project Information

Project IdentifiersProject ID: 212687
DEA: 06442544
EFIS: 0612000175
DIST-CO-RTE-PM06-KER-46,5-31.5-33.2
Award Date01/11/2018
Closeout Date11/19/2021
Work DescriptionCONVERT 2-LANE TO 4-LANE CONVENTIONAL HIGHWAY.
Location DescriptionKERN COUNTY NEAR LOST HILLS FROM 1.0 MILE EAST OF LOST HILLS ROAD TO 0.7 MILE EAST OF ROUTE 46/5 SEPARATION
QA Service Level1 (Verified on 03/12/2018)

Sample Information

Sample Taken Date06/26/2019 Sample Unique Key1
Date that the sample was received by the laboratory/organization performing the testing07/01/2019 Sample typeQuality Assurance
A brief description of the sampleHRC 555 T-Heads The quantity of what the sample constitutes16
From where was the sample collectedFabricator First name of sampler or witnessed byHitesh
Last name of sampler or witnessed byPatel Title of samplerQuality Assurance Inspector
Telephone number of sampler9168691602 Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameCMC San Bernardino
Transportation Laboratory (TL) NumberUnknown Inspector Lot Number from the Transportation Laboratory (TL) FormL131-135-19
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Headed Bars Production or Authorization TestingProduction Testing
Rebar Heat Number(s)6503153102 Head Manufacturer Lot Number(s)3
Rebar Size9 Headed Bar Model Name555 T Heads
Size of HeadReduced Size - 4x Head Connection TypeForged
Head ShapeCircular Rebar ManufacturerGerdau
Head ManufacturerGerdau RSW Head FabricatorGerdau HRC
Material Standard CodeASTM A706 Headed Bar Unique IDNot set

Test Details

DIME Sample ID: 2019-06-26-1
DIME Test ID: 2019-06-26-1-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2019-07-03

Test Results


Number of Headed Bar Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 07/03/2019
UTM: 400KIP
Temperature: 72 F
NumLot #Area (sqin)Peak Load (lbf)Tensile Strength (psi)CommentsTested By
1319800098000Bar BrokeFred

General comments (publicly viewable) (Max 1000 characters): Bar Broke; OK Necking
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 7/3/2019 ✔