Summary for Test 2019-06-06-10-9

Test performed: CTM 202-November 2011

Project Information

Project IdentifiersProject ID: 210569
DEA: 083555V4
EFIS: 0814000086
DIST-CO-RTE-PM08-SBD-15-42.5/46.0
Award Date11/05/2015
Closeout Date01/18/2022
Work DescriptionWIDEN I-15, RECONSTRUCT 3 IC'S, CONSTRUCT 2 NEW BR AND WIDEN 3 BR.
Location DescriptionSAN BERNARDINO COUNTY IN VICTORVILLE FROM 0.5 MILE NORTH OF MOJAVE DRIVE TO 1.5 MILE NORTH OF STODDARD WELLS ROAD OVERCROSSING
QA Service Level1 (Verified on 10/15/2015)

Sample Information

Sample Taken Date06/06/2019 Sample Unique Key10
Date that the sample was received by the laboratory/organization performing the testing06/10/2019 Sample typeVerification
A brief description of the sample1 HMA-A-SP R15 The quantity of what the sample constitutesPSE 4 bags
From where was the sample collectedManufacturer First name of sampler or witnessed byEkene
Last name of sampler or witnessed byEzeoke Title of sampler
Telephone number of sampler Laboratory sample identification0335A-19
Linked DIME Sample ID The fabricator/manufacturer/facility nameBlue Diamond Oro Grande, Cemex White Mountain
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)Blue Diamond Oro Grande, Cemex White Mountain
The fabricator's/manufacturer's product name for the sample1 HMA-A-SP R15 The fabricator/manufacturer designation for the sample300222-WM
The plant numberUnknown A detailed description of where the material sample was collectedBelt Cut at Plant
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size1 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2019-06-06-10
DIME Test ID: 2019-06-06-10-9
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2019-07-03

Test Results


What size aggregate is being tested?: Combined Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Calculated
Tester's full name: Husni Ankir
Date of test: 06/20/2019
Sieve SizeCumulative Percent Passing
100 %
100 %
100 %
100 %
100 %
100 %
100 %
93 %
57 %
42 %
32 %
23 %
16 %
10 %
7 %
General comments (publicly viewable) (Max 1000 characters): RAP Gradation After Ignition Oven

Test was verified on 7/3/2019 ✔