Summary for Test 2019-05-30-9-1
Test performed: ASTM C39-10Project Information
| Project Identifiers | Project ID: 210735 DEA: 071193U4 EFIS: 0713000007 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-10-37.2/42.4 |
| Award Date | 11/16/2015 |
| Closeout Date | 07/11/2022 |
| Work Description | CONSTRUCT HOV LANES, WIDEN BRIDGES, AND REALIGN RAMPS. |
| Location Description | IN LA COUNTY FROM CITRUS STREET IN WEST COVINA TO ROUTE 57 IN POMONA |
| QA Service Level | 1 (Verified on 03/07/2016) |
Sample Information
| Sample Taken Date | 05/30/2019 | Sample Unique Key | 9 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/31/2019 |
| Sample type | Quality Assurance | A brief description of the sample | 6x12 concrete cylinders |
| The quantity of what the sample constitutes | 4 | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Daniel | Last name of sampler or witnessed by | meza |
| Title of sampler | ASR | Telephone number of sampler | |
| Laboratory sample identification | 946-4762 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | na | Transportation Laboratory (TL) Number | 14762 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Austin Vault Walls East West Side and Midle | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | 3F40L003 |
|---|---|---|---|
| The truck number from where the sample was collected | 647 | The batch plant ticket number from where the sample was collected | 101144017 |
| Concrete batch plant | Unknown | The fabricator/manufacturer designation for the sample | ATKINSON |
| A detailed description of where the material sample was collected | Austin Vault Walls East West Side and Midle | Where the material sample would have been placed if not sampled | Austin Vault Walls East West Side and Midle |
| From Lot No. | Unknown | Bag Lot No. | Unknown |
Test Details
DIME Sample ID: 2019-05-30-9
DIME Test ID: 2019-05-30-9-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2019-06-18
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: MM
Date of test: 06/13/2019
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.01 in
Average diameter of cylinder 2: 6.01 in
Maximum load on cylinder 1: 111900 lb
Maximum load on cylinder 2: 111600 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Age of specimen: 14 days
Cross sectional area of cylinder 1: 28.37 in^2
Cross sectional area of cylinder 2: 28.37 in^2
Compressive strength of cylinder 1: 3944.3 psi
Compressive strength of cylinder 2: 3933.7 psi
Compressive strength (to nearest 10 psi): 3940 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/18/2019 ✔