Summary for Test 2019-04-02-22-5
Test performed: ASTM D4791-10Project Information
| Project Identifiers | Project ID: 213912 DEA: 033H71U4 EFIS: 0319000051 |
|---|---|
| DIST-CO-RTE-PM | 03-BUT-70-8.8/12.1 |
| Award Date | 05/09/2019 |
| Closeout Date | 09/23/2021 |
| Work Description | WIDEN RDWY, RDWY EX, HMA & MODIFY ELECT SYSTEM. |
| Location Description | BUTTE COUNTY NEAR OROVILLE FROM 0.1 MILE SOUTH OF PALERMO ROAD TO 0.6 MILE NORTH OF OPHIR ROAD |
| QA Service Level | 1 (Verified on 02/21/2019) |
Sample Information
| Sample Taken Date | 04/02/2019 | Sample Unique Key | 22 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/10/2019 |
| Sample type | Quality Control | A brief description of the sample | QC for Assembling JMF |
| The quantity of what the sample constitutes | 500 tons | From where was the sample collected | Source |
| First name of sampler or witnessed by | Jon | Last name of sampler or witnessed by | Blumer |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Teichert Materials Hallwood | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-58-0006::HALLWOOD PLANT |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
| The plant number | Unknown | A detailed description of where the material sample was collected | HMA Plant Cold Feed |
| Where the material sample would have been placed if not sampled | Unknown | Primary Aggregate Nominal Size | 1/2 inch |
| The concrete mix design number | Unknown | Lot number | Unknown |
| Sublot number | Unknown | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2019-04-02-22
DIME Test ID: 2019-04-02-22-5
Testing Lab: Teichert Materials - Sacramento
Test Method: ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)
Test Release Date: 2019-06-05
Test Results
Method A - Percentage of Flat Particles, Elongated Particles, and Flat & Elongated Particles
Method B - Flat & Elongated Particles
Method: B
Determination: By Mass
Dimensional ratio used: 1:5
Input Type: Calculated
Tester's full name: Eric Gifford
Date of test: 04/02/2019
Weighted percentage of particles (by mass) that were flat and elongated: 1 %
Weighted percentage of particles (by mass) that were not flat and elongated: 99 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/5/2019 ✔