Summary for Test 2019-04-02-17-3
Test performed: AASHTO T209-12Project Information
| Project Identifiers | Project ID: 213912 DEA: 033H71U4 EFIS: 0319000051 |
|---|---|
| DIST-CO-RTE-PM | 03-BUT-70-8.8/12.1 |
| Award Date | 05/09/2019 |
| Closeout Date | 09/23/2021 |
| Work Description | WIDEN RDWY, RDWY EX, HMA & MODIFY ELECT SYSTEM. |
| Location Description | BUTTE COUNTY NEAR OROVILLE FROM 0.1 MILE SOUTH OF PALERMO ROAD TO 0.6 MILE NORTH OF OPHIR ROAD |
| QA Service Level | 1 (Verified on 02/21/2019) |
Sample Information
| Sample Taken Date | 04/02/2019 | Sample Unique Key | 17 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/10/2019 |
| Sample type | Quality Control | A brief description of the sample | QC for Assembling JMF |
| The quantity of what the sample constitutes | 500 tons | From where was the sample collected | Source |
| First name of sampler or witnessed by | Jon | Last name of sampler or witnessed by | Blumer |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Teichert Materials Hallwood | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Reclaimed Asphalt Pavement | RAP Source | Teichert Materials Hallwood |
|---|---|---|---|
| Aggregate Size | Unknown | Aggregate Source | Unknown |
| RAP Stockpile | Stockpile Size (tons) | Unknown | |
| Reclaimed Asphalt Pavement Mix Number | Not set |
Test Details
DIME Sample ID: 2019-04-02-17
DIME Test ID: 2019-04-02-17-3
Testing Lab: Teichert Materials - Sacramento
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2019-06-04
Test Results
Number of tests: 1
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Water
Input Type: Calculated
Tester's full name: Eric Gifford
Date of test: 04/18/2019
Specific Gravity for Sample 1: 2.582
Theoretical maximum density at 25°C (77°F): no data
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/4/2019 ✔