Summary for Test 2019-05-10-21-8
Test performed: CTM 217-June 2011Project Information
Project Identifiers | Project ID: 213551 DEA: 080K2934 EFIS: 0812000100 |
---|---|
DIST-CO-RTE-PM | 08-SBD-10-R36.8/R39.2 |
Award Date | 11/09/2018 |
Closeout Date | 09/15/2021 |
Work Description | PAVEMENT REHABILITATION AND CONTINUOUSLY REINFORCED CONCRETE PAVEMENT |
Location Description | SAN BERNARDINO COUNTY IN YUCAIPA FROM 0.2 MILE WEST OF LIVE OAK CANYON ROAD TO COUNTY LINE ROAD UNDERCROSSING |
QA Service Level | 1 (Verified on 12/31/2018) |
Sample Information
Sample Taken Date | 05/10/2019 | Sample Unique Key | 21 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/10/2019 |
Sample type | Per Request | A brief description of the sample | Aggregate Subbase |
The quantity of what the sample constitutes | 1 bag | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Ezz | Last name of sampler or witnessed by | Gayed |
Title of sampler | Resident Engineer | Telephone number of sampler | (909) 830-6954 |
Laboratory sample identification | 8587 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Caltrans | Transportation Laboratory (TL) Number | 8587 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | Unknown |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
The plant number | Unknown | A detailed description of where the material sample was collected | Exisiting Subbase |
Where the material sample would have been placed if not sampled | Unknown | Primary Aggregate Nominal Size | 3/4 inch |
The concrete mix design number | Unknown | Lot number | Unknown |
Sublot number | Unknown | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2019-05-10-21
DIME Test ID: 2019-05-10-21-8
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2019-06-11
Test Results
Number of tests: 2
Input Type: Calculated
Tester's full name: Satish Jain
Date of test: 05/11/2019
Temperature correction: 0
Temperature of solution: 72
Clay reading (test 1): 13.8
Sand reading (test 1): 1.7
Clay reading (test 2): 13.8
Sand reading (test 2): 1.8
Sand equivalent (test 1): 13
Sand equivalent (test 2): 13
Sand equivalent before temperature correction: 13
Sand equivalent after temperature correction: 13
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/4/2019 ✔