Summary for Test 2014-07-16-17456895-1
Test performed: ASTM C136-06Project Information
| Project Identifiers | Project ID: 209175 DEA: 030F2204 EFIS: 0300000072 |
|---|---|
| DIST-CO-RTE-PM | 03-ED-50-R30.7/R31.7 |
| Award Date | 02/25/2014 |
| Closeout Date | 07/30/2015 |
| Work Description | REPLACE BRIDGE. |
| Location Description | SLY PARK UNDERCROSSING |
| QA Service Level | 1 (Verified on 11/01/2013) |
Sample Information
| Sample Taken Date | 07/16/2014 | Sample Unique Key | 17456895 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/16/2014 |
| Sample type | Quality Control | A brief description of the sample | Bridge Deck Aggregate |
| The quantity of what the sample constitutes | 1 bag | From where was the sample collected | Source |
| First name of sampler or witnessed by | Andrew | Last name of sampler or witnessed by | Santos |
| Title of sampler | Not set | Telephone number of sampler | Not set |
| Laboratory sample identification | Not set | Linked DIME Sample ID | Not set |
| The fabricator/manufacturer/facility name | Folsom Ready Mix | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | Not set | |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | Folsom Ready Mix Stockpile |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | Not set | The fabricator/manufacturer designation for the sample | Not set |
| The plant number | Not set | A detailed description of where the material sample was collected | Folsom Ready Mix Stockpile |
| Where the material sample would have been placed if not sampled | Not set | Primary Aggregate Nominal Size | |
| The concrete mix design number | Lot number | Not set | |
| Sublot number | Not set | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2014-07-16-17456895
DIME Test ID: 2014-07-16-17456895-1
Testing Lab: Viking Construction Company, Incorporated - Rancho Cordova
Test Method: ASTM C136-06: Standard Test Method for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2014-07-17
Test Results
What type of gradation is being tested?: 1 in. x No. 4 - Coarse Aggregate
Input Type: Calculated
Tester's full name: Andrew Santos
Date of test: 07/16/2014
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 99 %
Cumulative percent passing the 3/4 in. sieve: 82 %
Cumulative percent passing the 1/2 in. sieve: 30 %
Cumulative percent passing the 3/8 in. sieve: 9 %
Cumulative percent passing the #4 sieve: 1 %
Cumulative percent passing the #8 sieve: 1 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/17/2014 ✔