Summary for Test 2019-05-21-2-2
Test performed: ASTM F606-14aProject Information
| Project Identifiers | Project ID: 3807 DEA: 07121844 EFIS: 0700000117 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-5-42.8/47.3 |
| Award Date | 12/06/2010 |
| Closeout Date | 06/30/2021 |
| Work Description | CONSTRUCT HOV LANES, RETAINING WALLS AND SOUND WALLS. |
| Location Description | LOS ANGELES COUNTY IN LOS ANGELES, GLENDALE, AND BURBANK FROM ROUTE 5/134 SEPARATION TO MAGNOLIA BOULEVARD OVERCROSSING |
| QA Service Level | 1 (Verified on 02/23/2012) |
Sample Information
| Sample Taken Date | 05/21/2019 | Sample Unique Key | 2 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/21/2019 |
| Sample type | Quality Assurance | A brief description of the sample | A325 HDG Rocap Assembiy |
| The quantity of what the sample constitutes | 16 | From where was the sample collected | Distributor |
| First name of sampler or witnessed by | Lorenzo | Last name of sampler or witnessed by | Garcia |
| Title of sampler | QA | Telephone number of sampler | 702 917-2503 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Industrial Bolt and Supply | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L115-085-19 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | 5028A325-1G AND 5032A325-1G |
|---|---|---|---|
| Heat Number(s) | 100894945 AND 100890222 | Nut Mfg. Lot Number(s) | 362406A |
| Washer Mfg. Lot Number(s) | 312019 | Bolt Specification | A325 |
| Bolt Length(s) | 1-3/4 AND 2" | Nut Specification | A563-2H |
| Washer Specification | F436 | Finish | Hot Dipped Galvanized |
| Diameter/Size | 1/2 | Bolt Mfg. Lot Number | 418605A AND 403427A |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | Dye coated | |
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2019-05-21-2
DIME Test ID: 2019-05-21-2-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2019-06-11
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Steve
Date of test: 06/03/2019
UTM: 400KIP
Temperature: 72 F
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
|---|---|---|---|---|---|---|---|
| 1 | 1A | 362406A | 1/2\" | 21563 | 95.92 | Nut Proof Load | Steve |
General comments (publicly viewable) (Max 1000 characters): Nut Proof Load
Test Graph
Source: Partner Data Point FileTest was verified on 6/4/2019 ✔