Summary for Test 2019-04-23-19-10

Test performed: CTM 643-June 2007

Project Information

Project IdentifiersProject ID: 214150
DEA: 080G8004
EFIS: 0812000111
DIST-CO-RTE-PM08-SBD-38-47.50/59.40
Award Date10/13/2020
Closeout Date11/01/2022
Work DescriptionRELINE OR REPLACE CULVERTS
Location DescriptionSAN BERNARDINO COUNTY IN AND NEAR BIG BEAR LAKE AT VARIOUS LOCATIONS FROM ZACA ROAD TO BIG BEAR LAKE DAM
QA Service Level1 (Verified on 05/09/2019)

Sample Information

Sample Taken Date04/23/2019 Sample Unique Key19
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/24/2019
Sample typePer Request A brief description of the sampleSoil
The quantity of what the sample constitutes1 bag From where was the sample collectedJob Site
First name of sampler or witnessed byJose Last name of sampler or witnessed byGuzman
Title of samplerMREA Telephone number of sampler(909) 829-6292
Laboratory sample identification8572 Linked DIME Sample ID2019-04-23-18
The fabricator/manufacturer/facility nameCaltrans Transportation Laboratory (TL) NumberC-8572
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sampleUnknown
The fabricator/manufacturer designation for the sampleUnknown A detailed description of where the material sample was collectedSR-38 EB, PM 58.9
Where the material sample would have been placed if not sampledUnknown

Test Details

DIME Sample ID: 2019-04-23-19
DIME Test ID: 2019-04-23-19-10
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 643-June 2007: Method for Determining Field and Laboratory Resistivity and pH Measurements for Soil and Water
Test Release Date: 2019-06-06

Test Results


The test method used?: Laboratory Resistivity Test for Soil
Input Type: Calculated
Tester's full name: Friday Ofoegbu
Date of test: 05/04/2019
Soil sample resistance (lab measure 1): no data Ohms
Soil sample resistance (lab measure 2): no data Ohms
Soil sample resistance (lab measure 3): no data Ohms
Soil sample resistance (lab measure 4): no data Ohms
Soil sample resistance (lab measure 5): no data Ohms
Soil sample resistance (lab measure 6): no data Ohms
Soil sample resistance (lab measure 7): no data Ohms
Soil sample resistance (lab measure 8): no data Ohms
Soil sample resistance (lab measure 9): no data Ohms
Soil sample resistance (lab measure 10): no data Ohms
Soil sample resistance (lab measure 11): no data Ohms
Soil sample resistance (lab measure 12): no data Ohms
Minimum soil resistance of the lab measurement: 6400 Ohms
Soil sample temperature: 23.3 C
Soil box constant: 1
pH of soil: 7.16
Minimum soil resistance corrected to 15.5: 7648 Ohms
Minimum soil resistivity at 15.5: 7648 Ohm-cm
General comments (publicly viewable) (Max 1000 characters): Estimated Life is 33 years.

Test was verified on 5/30/2019