Summary for Test 2014-06-13-6007565-6

Test performed: ASTM C39-10

Project Information

Project IdentifiersProject ID: 209175
DEA: 030F2204
EFIS: 0300000072
DIST-CO-RTE-PM03-ED-50-R30.7/R31.7
Award Date02/25/2014
Closeout Date07/30/2015
Work DescriptionREPLACE BRIDGE.
Location DescriptionSLY PARK UNDERCROSSING
QA Service Level1 (Verified on 11/01/2013)

Sample Information

Sample Taken Date06/13/2014 Sample Unique Key6007565
Date that the sample was received by the laboratory/organization performing the testing06/13/2014 Sample typeQuality Control
A brief description of the sampleAbutment 2 Stage 1 Concrete The quantity of what the sample constitutes6 cylinders
From where was the sample collectedSource First name of sampler or witnessed byAndrei
Last name of sampler or witnessed byPolischuk Title of samplerNot set
Telephone number of samplerNot set Laboratory sample identificationNot set
Linked DIME Sample IDNot set The fabricator/manufacturer/facility nameFolsom Ready Mix
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberSF718AFST0
The truck number from where the sample was collectedNot set The batch plant ticket number from where the sample was collected78390
Concrete batch plantNot set The fabricator/manufacturer designation for the sampleNot set
A detailed description of where the material sample was collectedAbutment 2 Stage 1 Where the material sample would have been placed if not sampledNot set
From Lot No.Not set Bag Lot No.Not set

Test Details

DIME Sample ID: 2014-06-13-6007565
DIME Test ID: 2014-06-13-6007565-6
Testing Lab: Viking Construction Company, Incorporated - Rancho Cordova
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2014-07-16

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed:
Input Type: Calculated
Tester's full name: Andrew Santos
Date of test: 07/11/2014
Comment on any defect in either specimen or caps (Max 250 Characters): no data
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/16/2014 ✔