Summary for Test 2019-04-16-42-3
Test performed: CTM 203-February 2008Project Information
| Project Identifiers | Project ID: 214151 DEA: 080R0104 EFIS: 0812000007 |
|---|---|
| DIST-CO-RTE-PM | 08-RIV-91-R0.3 |
| Award Date | 08/27/2025 |
| Closeout Date | Not set |
| Work Description | STR EXC, FURNISH PRECAST RCB CULVERT AND STR CONC RETAINING WALL. |
| Location Description | RIVERSIDE COUNTY NEAR CORONA AT 0.7 MILES WEST OF GREEN RIVER ROAD OVERCROSSING |
| QA Service Level | 1 (Verified on 05/09/2019) |
Sample Information
| Sample Taken Date | 04/16/2019 | Sample Unique Key | 42 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 04/18/2019 | Sample type | Per Request |
| A brief description of the sample | Soil | The quantity of what the sample constitutes | 1 Ziplock bag |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | Michael |
| Last name of sampler or witnessed by | Liao | Title of sampler | TE |
| Telephone number of sampler | (657( 328-6593 | Laboratory sample identification | 8560 |
| Linked DIME Sample ID | 2019-04-16-41 | The fabricator/manufacturer/facility name | Caltrans |
| Transportation Laboratory (TL) Number | None | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Soil | The fabricator's/manufacturer's product name for the sample | Unknown |
|---|---|---|---|
| The fabricator/manufacturer designation for the sample | Unknown | A detailed description of where the material sample was collected | Filed A-19-04, Sample Number S1 |
| Where the material sample would have been placed if not sampled | Unknown |
Test Details
DIME Sample ID: 2019-04-16-42
DIME Test ID: 2019-04-16-42-3
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 203-February 2008: Mechanical Analysis of Soils
Test Release Date: 2019-06-06
Test Results
What size aggregate is being tested?: Fine Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Input Type: Calculated
Tester's full name: Danny Ferrer
Date of test: 04/26/2019
Cumulative percent passing the 3/8 in. sieve: 81 %
Cumulative percent passing the #4 sieve: 70 %
Cumulative percent passing the #8 sieve: 59 %
Cumulative percent passing the #16 sieve: 47 %
Cumulative percent passing the #30 sieve: 37 %
Cumulative percent passing the #50 sieve: 28 %
Cumulative percent passing the #100 sieve: 21 %
Cumulative percent passing the #200 sieve: 16 %
General comments (publicly viewable) (Max 1000 characters): Hydrometer Results: 1 hour 5%, 24 hours 3%
Test was verified on 5/30/2019 ✔