Summary for Test 2019-05-20-18-1

Test performed: ASTM A934-13

Project Information

Project IdentifiersProject ID: 213572
DEA: 042J6704
EFIS: 0414000544
DIST-CO-RTE-PM04-ALA-238-14.5/16.5
Award Date11/29/2018
Closeout Date03/12/2020
Work DescriptionHIGHWAY LIGHTING
Location DescriptionALAMEDA COUNTY IN SAN LORENZO FROM 0.42 MILE WEST OF HESPERIAN BOULEVARD UNDERCROSSING TO 0.52 MILE EAST OF MISSION BOULEVARD UNDERCROSSING
QA Service Level1 (Verified on 05/06/2019)

Sample Information

Sample Taken Date05/20/2019 Sample Unique Key18
Date that the sample was received by the laboratory/organization performing the testing05/24/2019 Sample typeQuality Assurance
A brief description of the sampleA934 Purple Epoxy Coated Rebar The quantity of what the sample constitutes2
From where was the sample collectedJob Site First name of sampler or witnessed bySchmdtt
Last name of sampler or witnessed byAlex Title of sampler
Telephone number of sampler510-714-7080 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameFletcher Coating Co
Transportation Laboratory (TL) NumberC759528 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM7 - Epoxy Coated Rebar Rebar Heat Number(s)1202009395
Rebar Epoxy Batch Number(s) Rebar Coating SpecificationASTM A934
Rebar Size (#)5 Rebar Coating ColorPurple
Rebar ManufacturerNucor Rebar CoaterFletcher Coating Company
Rebar Powder ManufacturerUnknown Release NumberUnknown
Quality Assurance CodeA93419B14R2S18J27 A93419B15R2S18J27

Test Details

DIME Sample ID: 2019-05-20-18
DIME Test ID: 2019-05-20-18-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A934-13: Standard Specification for Epoxy-Coated Prefabricated Steel Reinforcing Bars (Epoxy-Coating)
Test Release Date: 2019-06-04

Test Results


Input Type: Measured
Tester's full name: Fred Saylor
Date of test: 05/28/2019
Lower spec. limit LSL: 7 mils
Upper spec. limit USL: 12 mils
Bar # for First Bar: 1
Bar # for Second Bar: 2
First Bar Side 1 mean value: 11.71
First Bar Side 2 mean value: 9.43
Second Bar Side 1 mean value: 13.28
Second Bar Side 2 mean value: 13.73
First Bar Mean: 10.57
Second Bar Mean: 13.5
Total mean value: 12.04
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/28/2019 ✔