Summary for Test 2019-05-13-6-3
Test performed: ASTM D624-00-re12Project Information
| Project Identifiers | Project ID: 212300 DEA: 044G3804 EFIS: 0412000463 |
|---|---|
| DIST-CO-RTE-PM | 04-SON-116-30.9/31.4 |
| Award Date | 03/15/2019 |
| Closeout Date | 02/16/2024 |
| Work Description | Construct Bridge, Retaining Walls, Traffic Signal |
| Location Description | SONOMA COUNTY NEAR COTATI FROM 0.3 MILE EAST OF HESSEL ROAD TO 0.1 MILE EAST OF BARTLESON ROAD |
| QA Service Level | 1 (Verified on 08/19/2019) |
Sample Information
| Sample Taken Date | 05/13/2019 | Sample Unique Key | 6 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 05/20/2019 | Sample type | Quality Assurance |
| A brief description of the sample | Bearing Pad | The quantity of what the sample constitutes | 3 |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | Kayla |
| Last name of sampler or witnessed by | Wallace | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Dynamic Rubber | |
| Transportation Laboratory (TL) Number | NA | Inspector Lot Number from the Transportation Laboratory (TL) Form | NA |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM1 - Elastomeric Bearing Pad | Mfg. Lot Number(s) | CR55-004-19, CR55-005-19, CR55-006-19 |
|---|---|---|---|
| Material/Compound/Elastomer ID | NA | Samples Representing | 75 |
| Description (size) | 1.15" x 3" x 12" and 16" | Comments | Unknown |
| Description (Number of Shims) | 2 | Type of Bearing Pad | Steel |
| Description (Thickness of Shims) | 14 gage | Manufacturer(s) | Dynamic Rubber |
| Batch Number | NA |
Test Details
DIME Sample ID: 2019-05-13-6
DIME Test ID: 2019-05-13-6-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM D624-00-re12: Standard Test Method for Tear Strength of Conventional Vulcanized Rubber and Thermoplastic Elastomers
Test Release Date: 2019-06-07
Test Results
Number of specimens tested: 3
Input Type: Measured
Tester's full name: Brian
Date of test: 05/22/2019
Humidity: 50 %
Temperature: 72 F
Sample 1 Median Thickness: 0.058 in
Sample 1 Tear Strength: 189.7 lbf / in
Sample 2 Median Thickness: 0.061 in
Sample 2 Tear Strength: 180.3 lbf / in
Sample 3 Median Thickness: 0.07 in
Sample 3 Tear Strength: 185.7 lbf / in
UTM: no data
Median of the Tear Strength Values: 185.7 lb/in
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point FileTest graph for Sample 1
Source: Partner Data Point File
Test graph for Sample 2
Source: Partner Data Point File
Test graph for Sample 3
Test was verified on 5/31/2019 ✔