Summary for Test 2019-04-12-12-1
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 66667 DEA: JMFPP EFIS: 0019000043 |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for submitting Sample information for JMF Prequalification Program. |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 04/12/2019 | Sample Unique Key | 12 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/22/2019 |
| Sample type | Verification | A brief description of the sample | 3/4 inch Type A HMA (eq. PG 70-10) |
| The quantity of what the sample constitutes | JMF Verification | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Martiniano | Last name of sampler or witnessed by | Ruiz |
| Title of sampler | Mat and Res Eng Aso Spc | Telephone number of sampler | 5592894416 |
| Laboratory sample identification | 019-005 | Linked DIME Sample ID | NA |
| The fabricator/manufacturer/facility name | Deer Creek Porterville | Transportation Laboratory (TL) Number | HDQTRS Lab |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | Not set | |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | Unknown |
| Sublot number | Unknown | HMA Mix Number | Not set |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2019-04-12-12
DIME Test ID: 2019-04-12-12-1
Testing Lab: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2019-05-29
Test Results
What temperature unit is used?: Fahrenheit
Input Type: Measured
Tester's full name: Gurpartap Grewal
Date of test: 04/29/2019
Test procedure used?: Method B
Mass of the specimen basket assembly: no data
Mass of the specimen and specimen basket assembly prior to ignition: no data
Mass of HMA Sample prior to ignition: 2107.1 g
Mass Loss: no data
Mass of aggregate remaining after ignition: 1985.8 g
Correction Factor (Percent by mass of HMA Specimen): 0.21 %
Moisture Content: 0.17 %
Temperature Compensation Factor: no data
Test Temperature: 538 F
Corrected Asphalt Binder Content: 5.38 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 5/22/2019 ✔