Summary for Test 2014-03-06-14007726-2
Test performed: CTM 643-June 2007Project Information
| Project Identifiers | Project ID: 3807 DEA: 07121844 EFIS: 0700000117 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-5-42.8/47.3 |
| Award Date | 12/06/2010 |
| Closeout Date | 06/30/2021 |
| Work Description | CONSTRUCT HOV LANES, RETAINING WALLS AND SOUND WALLS. |
| Location Description | LOS ANGELES COUNTY IN LOS ANGELES, GLENDALE, AND BURBANK FROM ROUTE 5/134 SEPARATION TO MAGNOLIA BOULEVARD OVERCROSSING |
| QA Service Level | 1 (Verified on 02/23/2012) |
Sample Information
| Sample Taken Date | 03/06/2014 | Sample Unique Key | 14007726 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/14/2014 |
| Sample type | Department Acceptance | A brief description of the sample | Structure Backfill |
| The quantity of what the sample constitutes | 2 Bags | From where was the sample collected | Other |
| First name of sampler or witnessed by | Unknown | Last name of sampler or witnessed by | Unknown |
| Title of sampler | Not set | Telephone number of sampler | Not set |
| Laboratory sample identification | 4107B | Linked DIME Sample ID | Not set |
| The fabricator/manufacturer/facility name | MSE Wall C Sta. 11 20. | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | Not set | |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | Soil | The fabricator's/manufacturer's product name for the sample | Not set |
|---|---|---|---|
| The fabricator/manufacturer designation for the sample | Not set | A detailed description of where the material sample was collected | MSE Wall C Sta. 11 20. |
| Where the material sample would have been placed if not sampled | Not set |
Test Details
DIME Sample ID: 2014-03-06-14007726
DIME Test ID: 2014-03-06-14007726-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 643-June 2007: Method for Determining Field and Laboratory Resistivity and pH Measurements for Soil and Water
Test Release Date: 2015-02-20
Test Results
The test method used?: Laboratory Resistivity Test
Input Type: Calculated
Tester's full name: Vincent Onoh
Date of test: 03/21/2014
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 2/20/2015 ✔