Summary for Test 2019-05-06-6-8

Test performed: ASTM B499-14

Project Information

Project IdentifiersProject ID: 213846
DEA: 041J5614
EFIS: 0419000117
DIST-CO-RTE-PM04-SM-101-0.0/6.7
Award Date12/21/2018
Closeout Date09/01/2022
Work DescriptionBarrier modifications, overhead signs, freeway lighting and electronic toll system components
Location DescriptionSANTA CLARA AND SAN MATEO COUNTIES IN PALO ALTO AND REDWOOD CITY FROM 0.3 MILE NORTH OF SAN ANTONIO ROAD TO WHIPPLE AVENUE OVERCROSSING
QA Service Level1 (Verified on 12/27/2018)

Sample Information

Sample Taken Date05/06/2019 Sample Unique Key6
Date that the sample was received by the laboratory/organization performing the testing05/13/2019 Sample typeQuality Assurance
A brief description of the sampleGalvanized / Plain Fastener Assembly The quantity of what the sample constitutes1 Assembly
From where was the sample collectedDistributor First name of sampler or witnessed byLoreno
Last name of sampler or witnessed byGarcia Title of samplerQA
Telephone number of sampler702 917-2503 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameUniversal Industrial Sales
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) FormL115-069-19
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s)3084906 Nut Mfg. Lot Number(s)Lot XC02 - HT MM17108958 HDG / Lot WWT2 - HT 188452 Plain
Washer Mfg. Lot Number(s)Lot 118307 - HT C82082 Bolt SpecificationF1554-55
Bolt Length(s)5' Nut SpecificationA563- Grade DH
Washer SpecificationF436 FinishGalvanized / Plain
Diameter/Size3" Bolt Mfg. Lot Number
Rocap Test Requirement(s) Lubricant Requirements(s)Blue Wax Dye
Washer Inner Diameter(s) Bolt Mill SupplierNot set
Nut Mill SupplierNot set Washer Mill SupplierNot set

Test Details

DIME Sample ID: 2019-05-06-6
DIME Test ID: 2019-05-06-6-8
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Test Release Date: 2019-05-28

Test Results


Input Type: Calculated
Tester's full name: Fred Saylor
Date of test: 05/21/2019
Sample No.: 1A
Rocap Number: no data
Heat Number(s): no data
Mfg. Lot Number: LOT 118307 - HT C82082
Finish Coating: ASTM F2329 - Hot Dip
Product Markings: B
Size: 3 in
Bolt Length: no data
Measurement Average: 6.01 mils
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/21/2019 ✔