Summary for Test 2019-03-25-22-1

Test performed: AASHTO T335-09r13

Project Information

Project IdentifiersProject ID: 66667
DEA: JMFPP
EFIS: 0019000043
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for JMF Prequalification Program.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date03/25/2019 Sample Unique Key22
Date that the sample was received by the laboratory/organization performing the testing04/29/2019 Sample typeVerification
A brief description of the sampleSized Untreated Aggregate (Dispute Resolution of JMF) The quantity of what the sample constitutesDispute Resolution of JMF Verification
From where was the sample collectedManufacturer First name of sampler or witnessed byMark
Last name of sampler or witnessed byHuddleston Title of samplerMat and Res Eng Aso
Telephone number of sampler Laboratory sample identification019-006
Linked DIME Sample IDNA The fabricator/manufacturer/facility namePapich Construction
Transportation Laboratory (TL) NumberHDQTRS Lab Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-10-0006::AVENAL AGGREGATES
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedFrom the plant
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size1/2 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2019-03-25-22
DIME Test ID: 2019-03-25-22-1
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)
Test Release Date: 2019-05-09

Test Results


Method: 2 - Individual Fracture Determination
Aggregate Size and Fracture Type: Coarse 1 and 2 Faced and Fine 1 Faced
Input Type: Calculated
Tester's full name: Ryan Kester
Date of test: 05/06/2019
Weighted average percentage of fractured, coarse, 2 faced particles: 83 %
Weighted average percentage of fractured, coarse, 1 faced particles: 94 %
Percentage of fractured, fine, 1 faced particles tested: 98 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/9/2019