Summary for Test 2019-03-25-22-6

Test performed: AASHTO T84-14

Project Information

Project IdentifiersProject ID: 66667
DEA: JMFPP
EFIS: 0019000043
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for JMF Prequalification Program.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date03/25/2019 Sample Unique Key22
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/29/2019
Sample typeVerification A brief description of the sampleSized Untreated Aggregate (Dispute Resolution of JMF)
The quantity of what the sample constitutesDispute Resolution of JMF Verification From where was the sample collectedManufacturer
First name of sampler or witnessed byMark Last name of sampler or witnessed byHuddleston
Title of samplerMat and Res Eng Aso Telephone number of sampler
Laboratory sample identification019-006 Linked DIME Sample IDNA
The fabricator/manufacturer/facility namePapich Construction Transportation Laboratory (TL) NumberHDQTRS Lab
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-10-0006::AVENAL AGGREGATES
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedFrom the plant
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size1/2 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2019-03-25-22
DIME Test ID: 2019-03-25-22-6
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Test Release Date: 2019-05-09

Test Results


Input Type: Measured
Tester's full name: Bang Nguyen
Date of test: 05/08/2019
Mass of saturated surface dry sample (before pycnometer) (S): 500.7 grams
Mass of the pycnometer with water and aggregate (C): 985.2 grams
Mass of the pycnometer with water (B): 676.4 grams
Mass of the oven dried sample (before pycnometer) (A): 489 grams
Mass of the saturated surface dry aggregate (for absorption) (S): 500.7 grams
Mass of the oven dry aggregate (for absorption) (A): 489 grams
Test Sample Preparation: Total Saturation
Bulk specific gravity: 2.548
Bulk specific gravity (SSD Basis): 2.609
Apparent specific gravity: 2.714
Absorption: 2.4 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/9/2019