Summary for Test 2019-01-16-18-2

Test performed: AASHTO T48-17

Project Information

Project IdentifiersProject ID: 99999
DEA: 0322222
DIST-CO-RTE-PM03-SAC,OMG-888,99,80-0.6-0.6
Award DateNot set
Closeout DateNot set
Work DescriptionTHIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
Location DescriptionTHIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
QA Service Level (Verified on 04/05/2013)

Sample Information

Sample Taken Date01/16/2019 Sample Unique Key18
Date that the sample was received by the laboratory/organization performing the testing01/16/2019 Sample typeQuality Control
A brief description of the sampletest The quantity of what the sample constitutes1
From where was the sample collectedSource First name of sampler or witnessed bytest
Last name of sampler or witnessed bytest Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nametest
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance Grade5
ModifiedNot set Lot numberNot set
Sublot numberNot set Tank numberNot set
Time of sampleNot set HMA SupplierNot set
Certified Asphalt SupplierNot set MultigradeNot set
Multigrade TypeNot set Asphalt Binder Mix NumberNot set
HMA TypeNot set HMA Supplier Mix ID NumberNot set

Test Details

DIME Sample ID: 2019-01-16-18
DIME Test ID: 2019-01-16-18-2
Testing Lab: CT HQ - Sacramento Materials Management Branch Field Office
Test Method: AASHTO T48-17: Standard Method of Test for Flash Point of Asphalt Binder by Cleveland Open Cup
Test Release Date: 2019-10-22

Test Results


Units of measurement for Observed Flash Point (C or F) and Ambient barometric pressure (kP or mmHg): Celsius and kilopascals
Input Type: Measured
Tester's full name: Bob Scott
Date of test: 05/02/2019
Observed Flash Point: 12 C
Ambient Barometric Pressure: 23 kP
Cleveland Open-Cup Flash Point in Celsius: 32 C
General comments (publicly viewable) (Max 1000 characters): test. pls ignore.

Test was verified on 10/22/2019 ✔