Summary for Test 2019-04-18-2-5
Test performed: ASTM A615-15Project Information
Project Identifiers | Project ID: 212618 DEA: 044G0564 EFIS: 0417000154 |
---|---|
DIST-CO-RTE-PM | 04-ALA-680-M2.4/M12.4 |
Award Date | 11/16/2017 |
Closeout Date | 12/08/2022 |
Work Description | ROADWAY REHAB, BRIDGE REPLACEMENT, RET. WALLS, TOLL SYSTEMS |
Location Description | FREMONT AND AT SUNOL FROM MISSION BOULEVARD SEPARATION TO KOOPMAN ROAD UNDERCROSSING |
QA Service Level | 1 (Verified on 10/16/2017) |
Sample Information
Sample Taken Date | 04/18/2019 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/22/2019 |
Sample type | Quality Assurance | A brief description of the sample | treaded bar with nuts |
The quantity of what the sample constitutes | 150 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Ed | Last name of sampler or witnessed by | Fleming |
Title of sampler | Telephone number of sampler | 707-310-2029 | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Williams Form Eng | Transportation Laboratory (TL) Number | 741315 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B10-128-19 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM5 - Threaded Bar | Production or Authorization Testing | Authorization Testing |
---|---|---|---|
Threaded Bar Specification | ASTM A615 | Threaded Bar Grade | 75 |
Threaded Bar Type | Plain | Rebar Size | 9 |
Nut Specification for Threaded Bar | ASTM A29 | System Manufacturer | Williams Form Eng |
Epoxy Coating Color | NA | Threaded Bar Application | Soil Nail |
Coating Standards | Uncoated | Bar Heat Number(s) | 100798249,100798250,100798251 |
Nut Heat Number(s) | 8297854 | Bar Lot Number | 1 249,2 250,3 251 |
Nut Lot Number | 9J7D | Coupler Heat Number(s) | Unknown |
Coupler Grade | Unknown |
Test Details
DIME Sample ID: 2019-04-18-2
DIME Test ID: 2019-04-18-2-5
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A615-15: Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2019-05-09
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 05/02/2019
UTM: 400KIP
Temperature: 72 F
Num | Sample | Size | Mfg Lot | Area (sqin) | Tensile Strength (psi) | Stress at Offset (psi) | Total Elongation (%) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|---|
1 | 3 | #9 Bar Heat# 100798251, Nut Lot #9J7D | B10-128-19 | 1 | 120494 | 85096 | 11.2 | A615 Threaded Bar and Nut | Brian |
General comments (publicly viewable) (Max 1000 characters): A615 Threaded Bar and Nut
Test Graph
Source: Partner Data Point FileTest was verified on 5/2/2019 ✔