Summary for Test 2017-04-03-10-1
Test performed: AASHTO T27-14Project Information
| Project Identifiers | Project ID: 213793 DEA: 060W7004 EFIS: 0617000283 |
|---|---|
| DIST-CO-RTE-PM | 06-FRE-33-24.3/R29.0,R39.9/44.5 |
| Award Date | 01/24/2019 |
| Closeout Date | 08/20/2021 |
| Work Description | COLD PLANE AC PAVEMENT, PLACE HMA RESURFACING. |
| Location Description | FRESNO COUNTY ABOUT 7.8 MILES NORTH OF COALINGA FROM NORTH JUNCTION ROUTE 198 TO SOUTH JUNCTION ROUTE 33/5 AND FROM 0.1 MILE NORTH OF NORTH JUNCTION ROUTE 33/5 TO EL PROGRESSIO ROAD |
| QA Service Level | 1 (Verified on 01/09/2019) |
Sample Information
| Sample Taken Date | 04/03/2017 | Sample Unique Key | 10 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 04/03/2017 | Sample type | Quality Control |
| A brief description of the sample | Bin #1 1/2 inch untreated (Dispute Resolution) | The quantity of what the sample constitutes | JMF HMA Design Data (Dispute Resolution) |
| From where was the sample collected | Source | First name of sampler or witnessed by | SPM |
| Last name of sampler or witnessed by | Avenal | Title of sampler | NA |
| Telephone number of sampler | 805-473-3016 | Laboratory sample identification | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | SPM-Avenal | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Not set | Structure name | Not set |
| Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-10-0006::AVENAL AGGREGATES |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | SPM-Avenal | The fabricator/manufacturer designation for the sample | Unknown |
| The plant number | Unknown | A detailed description of where the material sample was collected | Plant |
| Where the material sample would have been placed if not sampled | Unknown | Primary Aggregate Nominal Size | 1/2 inch |
| The concrete mix design number | Unknown | Lot number | Unknown |
| Sublot number | Unknown | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2017-04-03-10
DIME Test ID: 2017-04-03-10-1
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2019-05-08
Test Results
What type of gradation is being tested?: HMA Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): Yes
Has the fine aggregate sample been reduced?: No
Input Type: Calculated
Tester's full name: G3 Quality, Inc.
Date of test: 04/03/2017
| Cumulative Percent Passing | ||||||
|---|---|---|---|---|---|---|
| % | ||||||
| 100 % | ||||||
| 100 % | ||||||
| 100 % | ||||||
| 59 % | ||||||
| 6 % | ||||||
| 6 % | ||||||
| 3 % | ||||||
| 2 % | ||||||
| 2 % | ||||||
| 1 % | ||||||
| 1 % | ||||||
| 0.5 % | ||||||
| 0 % | ||||||
General comments (publicly viewable) (Max 1000 characters): JMF Renewal Dispute Resolution - HQ is handling the dispute by performing a full JMF verifcation through the Aggregate and HMA Labs. JMF served Project ID: 0617000283.
Test was verified on 5/1/2019 ✔