Summary for Test 2019-04-24-13-5
Test performed: AASHTO T269-14Project Information
| Project Identifiers | Project ID: 66667 DEA: JMFPP EFIS: 0019000043 |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for submitting Sample information for JMF Prequalification Program. |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 04/24/2019 | Sample Unique Key | 13 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/24/2019 |
| Sample type | Quality Control | A brief description of the sample | 1/2 inch Type A HMA (PG 64-10) |
| The quantity of what the sample constitutes | 24 boxes | From where was the sample collected | Source |
| First name of sampler or witnessed by | Escobar | Last name of sampler or witnessed by | Escobar |
| Title of sampler | QC Operations Supervisor | Telephone number of sampler | |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Granite Construction Company | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | Not set | |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 1/2 inch | Lot number | Unknown |
| Sublot number | Unknown | HMA Mix Number | Not set |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2019-04-24-13
DIME Test ID: 2019-04-24-13-5
Testing Lab: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Test Release Date: 2019-05-06
Test Results
Number of tests: 3
Is the sample lab compacted or field compacted?:
Input Type: Calculated
Tester's full name: GARCO Testing Laboratories
Date of test: 02/11/2019
| 1 | 2 | 3 | |
|---|---|---|---|
3.7 % | 3.5 % | 3.6 % | |
3.6 % |
General comments (publicly viewable) (Max 1000 characters): AASHTO T 269 Air Voids Content