Summary for Test 2019-04-24-18-7
Test performed: AASHTO T335-09r13Project Information
| Project Identifiers | Project ID: 66667 DEA: JMFPP EFIS: 0019000043 |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for submitting Sample information for JMF Prequalification Program. |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 04/24/2019 | Sample Unique Key | 18 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/24/2019 |
| Sample type | Quality Control | A brief description of the sample | Combined 1/2 inch Type A (untreated, Virgin) |
| The quantity of what the sample constitutes | 24 boxes | From where was the sample collected | Source |
| First name of sampler or witnessed by | Escobar | Last name of sampler or witnessed by | Escobar |
| Title of sampler | QC Operations Supervisor | Telephone number of sampler | |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Granite Construction Company | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | Not set | |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-39-0002::VERNALIS |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
| The plant number | Unknown | A detailed description of where the material sample was collected | Stockpile @ Plant |
| Where the material sample would have been placed if not sampled | Unknown | Primary Aggregate Nominal Size | 1/2 inch |
| The concrete mix design number | Unknown | Lot number | Unknown |
| Sublot number | Unknown | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2019-04-24-18
DIME Test ID: 2019-04-24-18-7
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)
Test Release Date: 2019-05-06
Test Results
Method: 2 - Individual Fracture Determination
Aggregate Size and Fracture Type: Coarse 1 and 2 Faced and Fine 1 Faced
Input Type: Calculated
Tester's full name: GARCO Testing Laboratories
Date of test: 02/11/2019
Weighted average percentage of fractured, coarse, 2 faced particles: 99 %
Weighted average percentage of fractured, coarse, 1 faced particles: 100 %
Percentage of fractured, fine, 1 faced particles tested: 100 %
General comments (publicly viewable) (Max 1000 characters): AASHTO T 335 Method 2
Crushed Particles, coarse (1 face)
Crushed Particles, coarse (2 faces)
Crushed Particles, fine (1 face)
Test was verified on 4/29/2019 ✔