Summary for Test 2019-04-10-17-5
Test performed: ASTM D4791-10Project Information
Project Identifiers | Project ID: 212512 DEA: 120M9604 EFIS: 1213000068 |
---|---|
DIST-CO-RTE-PM | 12-ORA-73-22.5/25.7 |
Award Date | 12/01/2017 |
Closeout Date | 03/03/2020 |
Work Description | COLDPLANE AC PVMTS , UPGRADE MBGR, CURB RAMPS AND CRASH CUSHION. |
Location Description | IRVINE AND NEWPORT BEACH FROM BONITA CANYON DRIVE/FORD ROAD UNDERCROSSING TO 0.2 MILE SOUTH OF RED HILL AVENUE OVERCROSSING |
QA Service Level | 1 (Verified on 03/22/2018) |
Sample Information
Sample Taken Date | 04/10/2019 | Sample Unique Key | 17 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/15/2019 |
Sample type | Verification | A brief description of the sample | 1/2 OGFC |
The quantity of what the sample constitutes | JMF 3 bags | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | RJ | Last name of sampler or witnessed by | Noble Company |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 0230O-19 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Hanson Aggregates | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | Not set | |
Structure name | Not set |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-33-0035::EAGLE VALLEY QUARRY |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | 1/2 OGFC PG 64-10 | The fabricator/manufacturer designation for the sample | 43R001SPO |
The plant number | Unknown | A detailed description of where the material sample was collected | Belt Cut at Plant |
Where the material sample would have been placed if not sampled | Unknown | Primary Aggregate Nominal Size | 1/2 inch |
The concrete mix design number | Unknown | Lot number | Unknown |
Sublot number | Unknown | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2019-04-10-17
DIME Test ID: 2019-04-10-17-5
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)
Test Release Date: 2019-05-07
Test Results
Method A - Percentage of Flat Particles, Elongated Particles, and Flat & Elongated Particles
Method B - Flat & Elongated Particles
Method: B
Determination: By Mass
Dimensional ratio used: 1:5
Input Type: Calculated
Tester's full name: Satish Jain
Date of test: 04/23/2019
Weighted percentage of particles (by mass) that were flat and elongated: 6 %
Weighted percentage of particles (by mass) that were not flat and elongated: 94 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/30/2019 ✔