Summary for Test 2019-04-05-11-8

Test performed: AASHTO T304-11

Project Information

Project IdentifiersProject ID: 213527
DEA: 081E5604
EFIS: 0814000050
DIST-CO-RTE-PM08---
Award Date11/19/2018
Closeout Date06/23/2021
Work DescriptionNot set
Location DescriptionNot set
QA Service Level1 (Verified on 06/23/2021)

Sample Information

Sample Taken Date04/05/2019 Sample Unique Key11
Date that the sample was received by the laboratory/organization performing the testing04/10/2019 Sample typeVerification
A brief description of the sampleRWMA-G-SP The quantity of what the sample constitutesJMF 4 bags
From where was the sample collectedManufacturer First name of sampler or witnessed byVulcan
Last name of sampler or witnessed byCorona Title of sampler
Telephone number of sampler Laboratory sample identification0220G-19
Linked DIME Sample ID The fabricator/manufacturer/facility nameVulcan Materials - Corona
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-33-0027::CORONA QUARRY
The fabricator's/manufacturer's product name for the sampleRWMA-SP-G 3/4 The fabricator/manufacturer designation for the sample226110 CORD SJR
The plant numberUnknown A detailed description of where the material sample was collectedManufacturer
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size3/4 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2019-04-05-11
DIME Test ID: 2019-04-05-11-8
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)
Test Release Date: 2019-04-30

Test Results


What test method is performed?: Method A
Input Type: Calculated
Tester's full name: Satish Jain
Date of test: 04/16/2019
Bulk dry specific gravity: 2.591
Average uncompacted voids: 46.1 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 4/23/2019 ✔