Summary for Test 2014-04-17-8000370-2
Test performed: CTM 643-June 2007Project Information
| Project Identifiers | Project ID: 3807 DEA: 07121844 EFIS: 0700000117 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-5-42.8/47.3 |
| Award Date | 12/06/2010 |
| Closeout Date | 06/30/2021 |
| Work Description | CONSTRUCT HOV LANES, RETAINING WALLS AND SOUND WALLS. |
| Location Description | LOS ANGELES COUNTY IN LOS ANGELES, GLENDALE, AND BURBANK FROM ROUTE 5/134 SEPARATION TO MAGNOLIA BOULEVARD OVERCROSSING |
| QA Service Level | 1 (Verified on 02/23/2012) |
Sample Information
| Sample Taken Date | 04/17/2014 | Sample Unique Key | 8000370 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 04/23/2014 | Sample type | Department Acceptance |
| A brief description of the sample | Structure Backfill | The quantity of what the sample constitutes | 2 Bags |
| From where was the sample collected | Source | First name of sampler or witnessed by | Unknown |
| Last name of sampler or witnessed by | Unknown | Title of sampler | Not set |
| Telephone number of sampler | Not set | Laboratory sample identification | 4131B |
| Linked DIME Sample ID | Not set | The fabricator/manufacturer/facility name | MSE Wall E Sta. 10 30 at 168.50 |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Not set | Structure name | Not set |
| Bid Item | Not set |
Material Information
| Material Type | Soil | The fabricator's/manufacturer's product name for the sample | Not set |
|---|---|---|---|
| The fabricator/manufacturer designation for the sample | Not set | A detailed description of where the material sample was collected | MSE Wall E Sta. 10 30 at 168.50 Inspection Element Level |
| Where the material sample would have been placed if not sampled | Not set |
Test Details
DIME Sample ID: 2014-04-17-8000370
DIME Test ID: 2014-04-17-8000370-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 643-June 2007: Method for Determining Field and Laboratory Resistivity and pH Measurements for Soil and Water
Test Release Date: 2014-11-19
Test Results
The test method used?: Laboratory Resistivity Test
Input Type: Calculated
Tester's full name: Vincent Onoh
Date of test: 04/27/2014
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 11/19/2014 ✔