Summary for Test 2019-03-13-3-2
Test performed: ASTM B499-14Project Information
Project Identifiers | Project ID: 211967 DEA: 101E8904 EFIS: 1016000093 |
---|---|
DIST-CO-RTE-PM | 10-SJ-5-26.5/27.0 |
Award Date | 03/02/2017 |
Closeout Date | 01/24/2020 |
Work Description | REPAIR BRIDGE CROSSFRAMES. |
Location Description | SAN JOAQUIN COUNTY IN STOCKTON AT STOCKTON CHANNEL VIADUCT |
QA Service Level | 1 (Verified on 07/24/2017) |
Sample Information
Sample Taken Date | 03/13/2019 | Sample Unique Key | 3 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/21/2019 |
Sample type | Quality Assurance | A brief description of the sample | 1" Flat Head Socket Head Cap Screw |
The quantity of what the sample constitutes | 5 | From where was the sample collected | Source |
First name of sampler or witnessed by | Hitesh | Last name of sampler or witnessed by | Patel |
Title of sampler | Quality Assurance Inspector | Telephone number of sampler | 9168691602 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Copper State Bolt and Nut Company | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L131-036-19 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
---|---|---|---|
Heat Number(s) | 188863 | Nut Mfg. Lot Number(s) | |
Washer Mfg. Lot Number(s) | Bolt Specification | ASTM A449-14 | |
Bolt Length(s) | Unknown | Nut Specification | N/A |
Washer Specification | N/A | Finish | HDG |
Diameter/Size | 1" | Bolt Mfg. Lot Number | |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2019-03-13-3
DIME Test ID: 2019-03-13-3-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Test Release Date: 2019-03-26
Test Results
Input Type: Calculated
Tester's full name: Brian Ewing
Date of test: 03/19/2019
Sample No.: 1A
Rocap Number: no data
Heat Number(s): no data
Mfg. Lot Number: 188863
Finish Coating: ASTM F2329 - Hot Dip
Product Markings: CSB 449
Size: 1 in
Bolt Length: 3.75 in
Measurement Average: 3.94 mils
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 3/19/2019 ✔