Summary for Test 2019-02-27-1-2

Test performed: CTM 553-1

Project Information

Project IdentifiersProject ID: 88888
DEA: SMTL-STOCK
EFIS: SMTL-STOCK
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date02/27/2019 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/14/2019
Sample typeDepartment Acceptance A brief description of the sampleRapid Setting Cement
The quantity of what the sample constitutes1 Bucket From where was the sample collectedJob Site
First name of sampler or witnessed byUnknown Last name of sampler or witnessed byUnknown
Title of sampler Telephone number of sampler
Laboratory sample identificationCM194901 Linked DIME Sample ID
The fabricator/manufacturer/facility nameCTS Rapid Set Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifierNot set
Structure nameNot set Bid ItemNot set

Material Information

Material TypeCementitious BrandCTS
MillUnknown Type of Cementitious MaterialRapid Set Cement

Test Details

DIME Sample ID: 2019-02-27-1
DIME Test ID: 2019-02-27-1-2
Testing Lab: CT HQ - Sacramento Cement Testing Laboratory
Test Method: CTM 553-1: Method for Testing Thermal Stability of Mortar Made with Hydraulic Cement
Test Release Date: 2022-05-11

Test Results


Input Type: Calculated
Tester's full name: Benjamin Lenz
Date of test: 03/15/2019
Average of test specimens broken to nearest 50 kPa, 23 ± 1.7°C for 48h: 5180 kPa
Average of test specimens broken to nearest 50 kPa, 50 ± 1°C for 48h: 4970 kPa
Thermal stability ratio: 96
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/11/2022