Summary for Test 2019-03-13-2-6

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 210837
DEA: 080J0804
EFIS: 0800000283
COOP: 081625
DIST-CO-RTE-PM08-RIV-15-34.7/51.6
Award Date04/17/2017
Closeout Date08/01/2024
Work Description(Alternative Delivery) DESIGN-BUILD OF THE INTERSTATE 15 EXPRESS LANES PROJECT
Location DescriptionRiverside County and SBD-15-0.0/1.3
QA Service Level1 (Verified on 05/08/2017)

Sample Information

Sample Taken Date03/13/2019 Sample Unique Key2
Date that the sample was received by the laboratory/organization performing the testing03/13/2019 Sample typeQuality Assurance
A brief description of the sampleFlash Welded Hoops The quantity of what the sample constitutes8
From where was the sample collectedFabricator First name of sampler or witnessed byDavid
Last name of sampler or witnessed byWeeks Title of samplerQA
Telephone number of sampler310-883-8369 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameRKR Steel Welding
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) FormL79-119-18
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)PL14203363
Hoop Manufacturer Lot Number(s)1 and 3 Material Standard CodeASTM A706
Material Grade60 Rebar Size5
Diameter of Hoop3'-2" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerNucor
Welding CompanyRKR Steel Welding Coating StandardsUncoated
Weld TypeFlash Welded

Test Details

DIME Sample ID: 2019-03-13-2
DIME Test ID: 2019-03-13-2-6
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2019-03-21

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 03/14/2019
UTM: 400KIP
Temperature: 72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
133#5/16mm0.312720087740Bar BrokeFred

General comments (publicly viewable) (Max 1000 characters): Bar Broke; OK Necking
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 3/14/2019 ✔