Summary for Test 2014-07-02-8308352-1

Test performed: ASTM C39-10

Project Information

Project IdentifiersProject ID: 209141
DEA: 07215954
EFIS: 0700001835
DIST-CO-RTE-PM07-LA-5-0.0/7.6
Award Date04/24/2014
Closeout Date07/14/2022
Work DescriptionWIDENING FREEWAY AND RECONSTRUCT OVERHEAD AND OVERCROSSING STRUCTURES
Location DescriptionLOS ANGELES COUNTY IN LA MIRADA, SANTA FE SPRINGS, NORWALK AND DOWNEY FROM ORANGE COUNTY/LOS ANGELES COUNTY LIMIT LINES TO 0.7 MILE NORTH OF ROUTE 605
QA Service Level1 (Verified on 06/02/2014)

Sample Information

Sample Taken Date07/02/2014 Sample Unique Key8308352
Date that the sample was received by the laboratory/organization performing the testingNot set Sample typeQuality Control
A brief description of the samplestructural concrete The quantity of what the sample constitutes4 cylinders
From where was the sample collectedOther First name of sampler or witnessed bybrett
Last name of sampler or witnessed bysoldano Title of samplerNot set
Telephone number of samplerNot set Laboratory sample identificationNot set
Linked DIME Sample IDNot set The fabricator/manufacturer/facility nameRobertsons Rialto
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberdfdfgd
The truck number from where the sample was collectedNot set The batch plant ticket number from where the sample was collected12345677
Concrete batch plantNot set The fabricator/manufacturer designation for the sampleNot set
A detailed description of where the material sample was collectedThe hopper of the concrete pump Where the material sample would have been placed if not sampledNot set
From Lot No.Not set Bag Lot No.Not set

Test Details

DIME Sample ID: 2014-07-02-8308352
DIME Test ID: 2014-07-02-8308352-1
Testing Lab: CT HQ - Sacramento Materials Management Branch Field Office
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2014-07-02

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: brett soldano
Date of test: 07/02/2014
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.00 in
Maximum load on cylinder 1: 234500 lb
Maximum load on cylinder 2: 456789 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 4
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: no data
Age of specimen: 28 days
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength of cylinder 1: 8295.0 psi
Compressive strength of cylinder 2: 16158.1 psi
Compressive strength (to nearest 10 psi): 12230 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/2/2014 ✔