Summary for Test 2018-12-12-1-4
Test performed: ASTM C109-16aProject Information
Project Identifiers | Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 12/12/2018 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/12/2018 |
Sample type | Annual Source Testing | A brief description of the sample | Type II Cement |
The quantity of what the sample constitutes | 1 Bucket | From where was the sample collected | Source |
First name of sampler or witnessed by | Unknown | Last name of sampler or witnessed by | Unknown |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | CM185857 | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Pan Pacific | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | Cementitious | Brand | Pan Pacific |
---|---|---|---|
Mill | CONCH China | Type of Cementitious Material | Silica Fume |
Test Details
DIME Sample ID: 2018-12-12-1
DIME Test ID: 2018-12-12-1-4
Testing Lab: CT HQ - Sacramento Cement Testing Laboratory
Test Method: ASTM C109-16a: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)
Test Release Date: 2019-08-12
Test Results
Will control cubes be used per ASTM C311?: no
Input Type: Measured
Tester's full name: Spencer Adams
Date of test: 03/12/2019
Age of specimen: 21 days
The amount of flow : 89 %
The amount of water used : 100 %
Compressive strength of 1st specimen : 4898 psi
Compressive strength of 2nd specimen: 4569 psi
Compressive strength of 3rd specimen : 4819 psi
Average Compressive strength (to nearest 10 psi): 4760 psi
General comments (publicly viewable) (Max 1000 characters): 28 day cubes but broken at 21 Days
Test was verified on 8/12/2019 ✔