Summary for Test 2019-02-15-1-6

Test performed: ASTM D638-Dec14

Project Information

Project IdentifiersProject ID: 213284
DEA: 060V4604
EFIS: 0616000181
DIST-CO-RTE-PM06-FRE,MAD-99,99-Var,26.8
Award Date06/11/2018
Closeout Date12/04/2019
Work DescriptionBRIDGE DECK OVERLAYS AND JOINT SEALS.
Location DescriptionFRESNO AND MADERA COUNTIES AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 12/19/2018)

Sample Information

Sample Taken Date02/15/2019 Sample Unique Key1
Date that the sample was received by the laboratory/organization performing the testing02/15/2019 Sample typeQuality Control
A brief description of the sample1 gallon can The quantity of what the sample constitutes12 tankers
From where was the sample collectedSource First name of sampler or witnessed byChris
Last name of sampler or witnessed byNunes Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameKwik bond and Reichhold
Transportation Laboratory (TL) NumberSacramento Caltrans lab Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypePolyester Mfg. Lot Number(s)1167897
Batch Number1167897 Mix number1167897

Test Details

DIME Sample ID: 2019-02-15-1
DIME Test ID: 2019-02-15-1-6
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM D638-Dec14: Standard Test Method for Tensile Properties of Plastics
Test Release Date: 2019-03-01

Test Results


Number of specimens tested: 6
Input Type: Measured
Tester's full name: Larry McCrum
Date of test: 03/01/2019
Conditioning procedure: 18/25/50+5/70
Speed of testing: 0.45 in/min
Sample 1 Width: 0.492 in
Sample 1 Thickness: 0.253 in
Sample 1 Area: 0.1245 in^2
Sample 1 Ultimate Strength Actual: 397.7 lbs
Sample 1 percent elongation: 64.3 %
Sample 1 Time: 4 MM:SS
Sample 2 Width: 0.491 in
Sample 2 Thickness: 0.246 in
Sample 2 Area: 0.1208 in^2
Sample 2 Ultimate Strength Actual: 353.3 lbs
Sample 2 percent elongation: 54.7 %
Sample 2 Time: 4 MM:SS
Sample 3 Width: 0.492 in
Sample 3 Thickness: 0.254 in
Sample 3 Area: 0.125 in^2
Sample 3 Ultimate Strength Actual: 394.6 lbs
Sample 3 percent elongation: 63.1 %
Sample 3 Time: 4 MM:SS
Sample 4 Width: 0.492 in
Sample 4 Thickness: 0.249 in
Sample 4 Area: 0.1225 in^2
Sample 4 Ultimate Strength Actual: 338.7 lbs
Sample 4 percent elongation: 47.7 %
Sample 4 Time: 3 MM:SS
Sample 5 Width: 0.492 in
Sample 5 Thickness: 0.25 in
Sample 5 Area: 0.123 in^2
Sample 5 Ultimate Strength Actual: 384.3 lbs
Sample 5 percent elongation: 63.5 %
Sample 5 Time: 4 MM:SS
Sample 6 Width: 0.492 in
Sample 6 Thickness: 0.246 in
Sample 6 Area: 0.121 in^2
Sample 6 Ultimate Strength Actual: 372.5 lbs
Sample 6 percent elongation: 60.1 %
Sample 6 Time: 4 MM:SS
Sample 1 Ultimate strength: 3194.4 psi
Sample 2 Ultimate strength : 2924.7 psi
Sample 3 Ultimate strength: 3156.8 psi
Sample 4 Ultimate strength: 2764.9 psi
Sample 5 Ultimate strength: 3124.4 psi
Sample 6 Ultimate strength : 3078.5 psi
Ultimate Strength Average: 3041 psi
Percent Elongation Average: 59 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 3/1/2019 ✔