Summary for Test 2014-03-28-10006580-2

Test performed: CTM 217-June 2011

Project Information

Project IdentifiersProject ID: 7427
DEA: 07215934
EFIS: 0700001833
DIST-CO-RTE-PM07-LA-5-2.4/4.0
Award Date08/14/2012
Closeout Date02/20/2020
Work DescriptionWiden and Realign Freeway and Construct Ped OC, OC and UC Structures.
Location DescriptionLOS ANGELES COUNTY IN SANTA FE SPRINGS AND NORWALK FROM 0.1 MILE NORTH OF CARMENITA ROAD OVERCROSSING TO 0.1 MILE NORTH OF SILVERBOW AVENUE PEDESTRIAN OVERCROSSING
QA Service Level1 (Verified on 11/26/2012)

Sample Information

Sample Taken Date03/28/2014 Sample Unique Key10006580
Date that the sample was received by the laboratory/organization performing the testing04/02/2014 Sample typeDepartment Acceptance
A brief description of the sampleClass 2 AB The quantity of what the sample constitutes2 Bags
From where was the sample collectedOther First name of sampler or witnessed byArnold
Last name of sampler or witnessed byTruong Title of samplerMREA
Telephone number of samplerNot set Laboratory sample identification4121B
Linked DIME Sample IDNot set The fabricator/manufacturer/facility name25th Street Recycle Plant
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)Unknown
The fabricator's/manufacturer's product name for the sampleNot set The fabricator/manufacturer designation for the sampleNot set
The plant numberNot set A detailed description of where the material sample was collectedI-5 South Shoemaker OC
Where the material sample would have been placed if not sampledNot set Primary Aggregate Nominal Size
The concrete mix design number Lot numberNot set
Sublot numberNot set Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2014-03-28-10006580
DIME Test ID: 2014-03-28-10006580-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2015-02-20

Test Results


Number of tests: 1
Input Type: Calculated
Tester's full name: Nemencio Daof
Date of test: 04/04/2014
Temperature correction: no data
Temperature of solution: no data
Clay reading (test 1): no data
Sand reading (test 1): no data
Sand equivalent (test 1): no data
Sand equivalent before temperature correction: no data
Sand equivalent after temperature correction: 43
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 2/20/2015 ✔