Summary for Test 2019-02-07-5-2
Test performed: ASTM F606-14aProject Information
| Project Identifiers | Project ID: 213074 DEA: 044G8904 EFIS: 0413000059 |
|---|---|
| DIST-CO-RTE-PM | 04-CC-580-5.8 |
| Award Date | 05/10/2018 |
| Closeout Date | 03/12/2020 |
| Work Description | BIDGE SEISMIC RETROFIT |
| Location Description | CONTRA COSTA COUNTY IN RICHMOND AT SCOFIELD AVENUE UNDERCROSSING |
| QA Service Level | 1 (Verified on 02/13/2018) |
Sample Information
| Sample Taken Date | 02/07/2019 | Sample Unique Key | 5 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/07/2019 |
| Sample type | Quality Assurance | A brief description of the sample | Connection Bolts |
| The quantity of what the sample constitutes | 4 | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Andre | Last name of sampler or witnessed by | Totari |
| Title of sampler | AMR | Telephone number of sampler | (510) 730-0387 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Cosmec | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | Not set | |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
|---|---|---|---|
| Heat Number(s) | Nut Mfg. Lot Number(s) | 410347C | |
| Washer Mfg. Lot Number(s) | D5910 | Bolt Specification | A325 |
| Bolt Length(s) | 7.5 | Nut Specification | A194 |
| Washer Specification | F436 | Finish | |
| Diameter/Size | 1 | Bolt Mfg. Lot Number | 373303 |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | Green | |
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2019-02-07-5
DIME Test ID: 2019-02-07-5-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2019-02-22
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Steve
Date of test: 02/14/2019
UTM: 400KIP
Temperature: 72 F
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
|---|---|---|---|---|---|---|---|
| 1 | 1A | 410347C | 1\" | 93683 | 416.72 | nut proof | Steve |
General comments (publicly viewable) (Max 1000 characters): nut proof
Test Graph
Source: Partner Data Point FileTest was verified on 2/15/2019 ✔